Motorola DSP96002 User Manual
Page 298
A - 110
DSP96002 USER’S MANUAL
MOTOROLA
FCMPM
Compare Magnitude
FCMPM
of Two Floating-Point Operands
Operation:
S2 - S1 (parallel data bus move)
Assembler Syntax:
FCMPM S1,S2 (move syntax - see the MOVE in-
struction description.)
Description:
Subtract the absolute value (magnitude) of the two operands as specified in the operation column above.
No result is stored; however, the condition codes are affected as described. This instruction differs from
FSUB when S1=S2; in this case, the result is always +0 and therefore, N is cleared. Note that this is true
even if S1, S2 are infinity.
Input Operand(s) Precision: SEP Floating-Point.
Output Operand Precision: n.a.
CCR Condition Codes:
(Note: Since there is no destination, there is no rounding and therefore the condition code bits are set as-
suming an infiite precision result)
C
- Not affected.
V
- Not affected.
Z
- Set if source operands are equal. Cleared otherwise.
N
- Set if result is negative. Cleared otherwise.
I
- Set if anyone of the operands is infinity. Cleared otherwise.
LR
- Not affected.
–
R
- Not affected.
A
- Not affected.
ER Status Bits:
INX
-Always cleared.
DZ
-Always cleared.
UNF
-Always cleared.
OVF
-Always cleared.
OPERR-Always cleared.
SNAN -Set if operand is a signaling NaN. Cleared otherwise.
NAN
-Set if result is a NaN. Cleared otherwise.
UNCC -Always cleared.