beautypg.com

Motorola DSP96002 User Manual

Page 298

background image

A - 110

DSP96002 USER’S MANUAL

MOTOROLA

FCMPM

Compare Magnitude

FCMPM

of Two Floating-Point Operands

Operation:

S2 - S1 (parallel data bus move)

Assembler Syntax:

FCMPM S1,S2 (move syntax - see the MOVE in-

struction description.)

Description:

Subtract the absolute value (magnitude) of the two operands as specified in the operation column above.

No result is stored; however, the condition codes are affected as described. This instruction differs from

FSUB when S1=S2; in this case, the result is always +0 and therefore, N is cleared. Note that this is true

even if S1, S2 are infinity.

Input Operand(s) Precision: SEP Floating-Point.

Output Operand Precision: n.a.

CCR Condition Codes:

(Note: Since there is no destination, there is no rounding and therefore the condition code bits are set as-
suming an infiite precision result)

C

- Not affected.

V

- Not affected.

Z

- Set if source operands are equal. Cleared otherwise.

N

- Set if result is negative. Cleared otherwise.

I

- Set if anyone of the operands is infinity. Cleared otherwise.

LR

- Not affected.

R

- Not affected.

A

- Not affected.

ER Status Bits:

INX

-Always cleared.

DZ

-Always cleared.

UNF

-Always cleared.

OVF

-Always cleared.

OPERR-Always cleared.

SNAN -Set if operand is a signaling NaN. Cleared otherwise.

NAN

-Set if result is a NaN. Cleared otherwise.

UNCC -Always cleared.