2 disconnecting and replacing a fru, Disconnecting and replacing a fru – FUJITSU SPARC ENTERPRISE M8000 User Manual

Page 99

background image

Chapter 4

FRU Removal Preparation

4-5

4.2.2

Disconnecting and Replacing a FRU

1. From the XSCF Shell prompt, use the replacefru command:

Note –

DDC_A is displayed only for the M8000.

The command is menu-driven. The example continues using a FAN unit.

The replacefru command will automatically test the status of the component after
the disconnecting off and replace has finished.

XSCF> replacefru

----------------------------------------------------------------

Maintenance/Replacement Menu

Please select a type of FRU to be replaced.

1. CMU/IOU(CPU Memory Board Unit/IO Unit)

2. FAN(Fan Unit)

3. PSU(Power Supply Unit)

4. XSCFU(Extended System Control Facility Unit)

5. DDC_A(DDC for BP_A)

----------------------------------------------------------------

Select [1-5|c:cancel] :

Select [1,2|c:cancel] :1

---------------------------------------------------

Maintenance/Replacement Menu

Please select a FAN to be replaced.

No. FRU

Status

--- --------------- ------------------

1. FAN_A#0

Normal

2. FAN_A#1

Normal

3. FAN_A#2

Normal

4. FAN_A#3

Normal

---------------------------------------------------

Select [1-4|b:back] :1

You are about to replace FAN_A#0.

Do you want to continue?[r:replace|c:cancel] :r

Please confirm the Check LED is blinking.

If this is the case, please replace FAN_A#0.

After replacement has been completed, please select[f:finish] :f