3 hot replacement, Hot replacement – FUJITSU SPARC ENTERPRISE M8000 User Manual
Page 305
Chapter 14
CD-RW/DVD-RW Drive Unit Replacement
14-9
18. From the OS, execute the cfgadm -c configure
TAPE_Ap_Id command to
configure the tape drive unit to the domain.
19. From the OS, execute the cfgadm -a command to verify that the status of
CD-RW/DVD-RW drive unit and the tape drive unit has changed from
"unconfigured" to "configured."
20. Close the door on the server, and lock it.
14.3
Hot Replacement
The procedure is as follows.
1. Unlock and open the appropriate door on the server.
For details, see
.
2. Stop all connection to the target CD-RW/DVD-RW drive unit.
3. Turn off power to the relevant domain.
From a console that is connected to XSCF, log in to XSCF, and execute the
poweroff -d
command.
The OS shutdown processing is executed for the relevant domain, and then the
power-off processing is executed.
4. Detach the target CD-RW/DVD-RW drive unit from the port.
From a terminal that is connected to XSCF, log in to XSCF, and execute the
cfgdevice -c detach -p <port no.> command.
5. Confirm that the target CD-RW/DVD-RW drive unit is unconfigured from the
domain.
From XSCF, execute cfgdevice -l to confirm that the relevant port is not displayed
in the current connection.
# cfgadm -c configure c0::rmt/0
#
cfgadm -a
Ap_Id
Type
Receptacle Occupant
Condition
:
c0::dsk/c0t4d0 CD-ROM connected
configured
unknown
c0::rmt/0
tape
connected
configured
unknown
: