beautypg.com

3 hot replacement, Hot replacement – FUJITSU SPARC ENTERPRISE M8000 User Manual

Page 305

background image

Chapter 14

CD-RW/DVD-RW Drive Unit Replacement

14-9

18. From the OS, execute the cfgadm -c configure

TAPE_Ap_Id command to

configure the tape drive unit to the domain.

19. From the OS, execute the cfgadm -a command to verify that the status of

CD-RW/DVD-RW drive unit and the tape drive unit has changed from
"unconfigured" to "configured."

20. Close the door on the server, and lock it.

14.3

Hot Replacement

The procedure is as follows.

1. Unlock and open the appropriate door on the server.

For details, see

Chapter 5

.

2. Stop all connection to the target CD-RW/DVD-RW drive unit.

3. Turn off power to the relevant domain.

From a console that is connected to XSCF, log in to XSCF, and execute the
poweroff -d

command.

The OS shutdown processing is executed for the relevant domain, and then the
power-off processing is executed.

4. Detach the target CD-RW/DVD-RW drive unit from the port.

From a terminal that is connected to XSCF, log in to XSCF, and execute the
cfgdevice -c detach -p <port no.> command.

5. Confirm that the target CD-RW/DVD-RW drive unit is unconfigured from the

domain.

From XSCF, execute cfgdevice -l to confirm that the relevant port is not displayed
in the current connection.

# cfgadm -c configure c0::rmt/0

#

cfgadm -a

Ap_Id

Type

Receptacle Occupant

Condition

:

c0::dsk/c0t4d0 CD-ROM connected

configured

unknown

c0::rmt/0

tape

connected

configured

unknown

: