FUJITSU SPARC ENTERPRISE M8000 User Manual
Page 57

Chapter 2
Product Overview and Troubleshooting
2-19
CHECK
Amber
Indicates the operating status of the SPARC Enterprise server.
Off
Normal state. Otherwise, this indicates that the main
line switches were switched off or a power failure
occurred.
Blinking
(*1)
Indicates that the operator panel is the maintenance
target device.
Lit
Indicates that the server cannot be started.
Note –
*1)If the maintenance target component is indicted by a blinking CHECK
LED, the LED may be called a locater.
TABLE 2-2
State Display by LED Combination (Operator Panel)
LED
Description of the state
POWER
XSCF
STANDBY
CHECK
Off
Off
Off
The main line switch is switched off.
Off
Off
On
The main line switch is switched on.
Off
Blinking
Off
The XSCF is being initialized.
Off
Blinking
On
An error occurred in the XSCF.
Off
On
Off
• The XSCF is on standby.
• The system is waiting for power-on of the air conditioning
system.
On
On
Off
• Warm-up standby processing is in progress (power-on is
delayed).
• The power-on sequence is in progress.
• The system is in operation.
Blinking
On
Off
• The power-off sequence is in progress.
• Fan termination is being delayed.
TABLE 2-1
State Display by the LEDs (Operator Panel) (Continued)
LED
Name
Light color
Description of function and state