Chapter 6

Replacement of CPU/Memory Board Unit (CMU), CPU, and DIMM

6-37

FIGURE 6-19

Mounting the CPU Module

Caution –

Each CPU Module has two CMU guide locks. Perform the work in such

a way that both guide locks are correctly set. Raise the insertion/extraction tool until
it touches the stopper and is perpendicular to the ground. The connector is securely
engaged when the insertion/extraction tool is raised vertically and it comes into
contact with the stopper. Do not forcibly raise the insertion/extraction tool further.

f. Reverse

Step 2

to

Step e

to remove the CPU Module insertion/extraction tool.

Caution –

After using the CPUM insertion/extraction tool, be sure to return it to

the storage location in the server.

6.5.2

Memory Module Mounting Conditions

This section describes memory module (DIMM) mounting conditions.