C H A P T E R

10

Operator Panel Replacement

This chapter explains the replacement procedures for the operator panel (OPNL). It
covers the following:

Section 10.1, “Overview of the Operator Panel” on page 10-1

Section 10.2, “Cold Replacement” on page 10-4

Cold replacement is the only swapping method that can be used for the OPNL. For
the definition of each type of swapping method, see

Section 4.1, “Types of

Replacement Procedures” on page 4-2

.

Note –

Operation on the operator panel requires a different key from the key for the

doors of the server. Both are managed by the system administrator.

Note –

If you replace the XSCF unit and the operator panel simultaneously, system

will not operate normally. Execute the showhardconf command or the
showstatus

command to confirm that the component replaced earlier is operating

normally, before replacing the subsequent FRU.

10.1

Overview of the Operator Panel

This section provides an overview of the OPNL and describes its mounting location.

The OPNL is used for the operation and condition display of the server. Active
maintenance is not supported. The OPNL is mounted on the front cover.