background image

6-10

SPARC Enterprise M8000/M9000 Servers Service Manual • August 2009

If you are upgrading an existing SPARC64 VI CPU module in an existing domain to
SPARC64 VII processors, continue with

Section 6.2.2.3, “Upgrading a SPARC64 VI

CPU Module to SPARC64 VII on an Existing Domain” on page 6-11

.

6.2.2.2

Adding a SPARC64 VII CPU Module to a Domain Configured
With SPARC64 VI

This procedure must be preceded by

Section 6.2.2.1, “Preparing to Add SPARC64 VII

Processors to an Existing Domain” on page 6-8

. If you have not completed that

procedure, do so before continuing.

1. Install the CMU in the server.

For adding the CPU, operate by hot replacement, referring to

Section 6.3, “Active

Replacement and Hot Replacement” on page 6-12

.

Note –

Do not fail to execute the diagnosis of newly mounted CMU in the

maintenance menu of replacefru(8) command.

2. Log in to the XSCF on an account with platform administrative privileges.

3. Confirm that the mounted CPU module has been recognized by the server, and

the error indicator asterisk (*) is not displayed.

4. Confirm no abnormality occurred by using showlogs error -v and

showstatus

(8) commands.

5. Move the key position on the operator panel from Service to Locked.

6. In case of addition, sets the following for the CMU.

Set up XSB.

Set up the LSB.

Add the XSB to the domain.

Refer to Chapter 2, "Setting Up XSCF," in the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide
for information
about these settings.

7. Power on the target domains.

XSCF> showhardconf -M

XSCF> showlogs error -v

XSCF> showstatus

XSCF> poweron -d

domain_id