beautypg.com

2 monitoring output, Monitoring output – FUJITSU SPARC ENTERPRISE M8000 User Manual

Page 66

background image

2-28

SPARC Enterprise M8000/M9000 Servers Service Manual • August 2009

2.6.2

Monitoring Output

To understand error conditions, collect monitoring output information, by using the
commands shown below.

TABLE 2-9

lists the commands for checking the monitoring output.

TABLE 2-8

Predictive Self Healing Message

Output displayed

Description

Nov 1 16:30:20 dt88-292 EVENT-TIME: Tue Nov 1 16:30:20 PST 2005

EVENT-TIME: the time stamp of
the diagnosis.

Nov 1 16:30:20 dt88-292 PLATFORM: SUNW,A70, CSN: -, HOSTNAME:
dt88-292

PLATFORM: A description of the
server encountering the problem.

Nov 1 16:30:20 dt88-292 SOURCE: eft, REV: 1.13

SOURCE: Information on the
Diagnosis Engine used to
determine the fault.

Nov 1 16:30:20 dt88-292 EVENT-ID:
afc7e660-d609-4b2f-86b8-ae7c6b8d50c4

EVENT-ID: The Universally
Unique event ID for this fault.

Nov 1 16:30:20 dt88-292 DESC:
Nov 1 16:30:20 dt88-292 A problem was detected in the PCI-Express
subsystem

DESC: A basic description of the
failure.

Nov 1 16:30:20 dt88-292 Refer to http://sun.com/msg/SUN4-8000-0Y for
more information.

WEBSITE: Where to find specific
information and actions for this
fault.

Nov 1 16:30:20 dt88-292 AUTO-RESPONSE: One or more device instances
may be disabled

AUTO-RESPONSE: What, if
anything, the system did to
alleviate any follow-on issues

Nov 1 16:30:20 dt88-292 IMPACT: Loss of services provided by the device
instances associated with this fault

IMPACT: A description of what
that response might have done.

Nov 1 16:30:20 dt88-292 REC-ACTION: Schedule a repair procedure to
replace the affected device. Use Nov 1 16:30:20 dt88-292 fmdump -v -u
EVENT_ID to identify the device or contact Sun for support.

REC-ACTION: A short description
of what the system administrator
should do.