SPARC Enterprise M8000/M9000 Servers Service Manual • August 2009

9. While grasping the eject/lock levers, properly align the crossbar unit with the

slot guide, and then gently insert it.

Caution –

If you are unable to obtain a torque screwdriver, finger tighten the clock

cable connectors. Do not secure them with a regular screwdriver.

Caution –

Do not forcibly push the crossbar unit in when inserting it. If the crossbar

unit is forcibly inserted despite the presence of any obstruction in a slot or any
problems with the connector pin, serious damage may result.

10. Lock the eject/lock levers to affix the crossbar unit to the back plane.

11. Push the eject/lock levers as far as they will go, and then push the knob screws

on the right and left eject/lock levers to lock them in position. If the knob
screws remain in position, the crossbar unit is securely mounted.

12. If a SPARC Enterprise M9000 server expansion cabinet is installed, connect

cables for connecting the base cabinet to the expansion cabinet crossbar unit.

a. To connect the cables, hold the cable connector covers and insert the

connectors perpendicularly with respect to the front plate of the XB unit
until they come into contact with the front plate.

b. Then, while ensuring that the cable weight does not cause the cable

connectors to become slanted, fix the data cable connectors in position with a
standard screwdriver while supporting the cable connector with one hand.

c. Use a torque screwdriver to secure the clock cable connector with the torque

of 0.2N*m (2.0kgf*cm).

Note –

After fixing the cable connectors in position, confirm that the connector

housing is securely affixed to the XB unit, and that it is not slanted sideways,
upward or downward. If the cable connectors are affixed slanted, the affixed part
will become unstable, leading to communication failure.

Caution –

Do not hang or yank the cable. Especially do not while the one side is

connected.

Caution –