beautypg.com

C.2 upc port, C.3 usb port, Upc port – FUJITSU SPARC ENTERPRISE M8000 User Manual

Page 492: Usb port, C.2 upc port c.3 usb port

background image

C-2

SPARC Enterprise M8000/M9000 Servers Service Manual • August 2009

C.2

UPC Port

C.3

USB Port

TABLE C-2

UPC Port

Setting

Pin No>

Signal name

Input/output

Description

1

ER

Output

Equipment power-on report signal

2

NC

Not connected

3

NC

Not connected

4

NC

Not connected

5

SG

Ground

6

*BPS

Input

UPS hardware error signal

7

*BTL

Input

Battery end of discharge warning
signal

8

NC

---

Not connected

9

*ACOFF

Input

Power failure detection signal

TABLE C-3

USB Port

Setting

Pin No>

Signal name

Name

Abbreviation

1

VBUS

Output

Power supply

2

-DATA

Input/output

Data

3

+DATA

Input/output

Data

4

GND

Ground

9 8 7 6

5 4 3 2 1

1 2 3 4