background image

4-6

SPARC Enterprise M8000/M9000 Servers Service Manual • August 2009

When the tests are complete the program will return to the original menu. Select
cancel to return to the XSCF Shell prompt.

Note –

The display may vary depending on the XCP version.

4.2.3

Configuring a FRU into a Domain

4.2.3.1

Configuring CMU/IOU

Perform the following procedure to configure a CMU or IOU when the Solaris OS is
operating:

Diagnostic tests for FAN_A#0 have started.

[This operation may take up to 2 minute(s)]

(progress scale reported in seconds)

0.....

30.....

60.....

90.....done

--------------------------------------------------

Maintenance/Replacement Menu

Status of the replaced unit.

FRU

Status

-------------

--------

FAN_A#0

Normal

--------------------------------------------------

The replacement of FAN_A#0 has completed, normally.[f:finish] :f

--------------------------------------------------

Maintenance/Replacement Menu

Please select a type of FRU to be replaced.

1. FAN

(Fan Unit)

2. PSU

(Power Supply Unit)

--------------------------------------------------

Select [1,2|c:cancel] : C

XSCF>