beautypg.com

2 active replacement, Active replacement, Table 13-1 – FUJITSU SPARC ENTERPRISE M8000 User Manual

Page 277

background image

Chapter 13

PCI Slot Device Replacement

13-3

For the following devices, replacement procedures have the same steps except that
LEDs to be checked, eject levers, and names used for status display are different.

PCI cassette (PCICS)

PCI card

IOU onboard device card (IOUA)

Link card

Note –

The steps of the replacement procedures for I/O boxes and link cards

mounted in external I/O expansion units, PCI cards, I/O boards, and power supply
units are basically the same as those described in this manual. For details, see the
External I/O Expansion Unit Installation and Service Manual.

The following explains the replacement procedure for a PCI card, which is a typical
example.

13.2

Active Replacement

The PHP function enables active replacement of PCI cassettes (PCICSs) and link
card. Active replacement cannot be performed for IOU onboard device cards
(IOUAs).

The active replacement procedure is as follows.

1. Unlock and open the appropriate door on the server.

For details, see

Chapter 5

.

TABLE 13-1

Abbreviated Name and Numbers of PCI Slots

Slot name

Abbreviated name and numbers

PCI slot

PCI#0 to 7