2 prtdiag command, 1 options, Options – FUJITSU SPARC ENTERPRISE M8000 User Manual
Page 77
Chapter 2
Product Overview and Troubleshooting
2-39
The following example shows output for one iostat command.
2.9.2
prtdiag
Command
The prtdiag command displays configuration and diagnostic information. The
diagnostic information identifies any failed component.
The prtdiag command is located in the
/usr/platform/platform-name/sbin/
directory.
Note –
The prtdiag command might indicate a slot number different than that
identified elsewhere in this document. This is normal.
2.9.2.1
Options
describes options for the prtdiag command and how those options can
help troubleshooting.
# iostat -En
c0t0d0
Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Model: ST3120026A
Revision: 8.01
Serial No: 3JT4H4C2
Size: 120.03GB <120031641600 bytes>
Media Error: 0 Device Not Ready: 0
No Device: 0 Recoverable: 0
Illegal Request: 0
c0t2d0
Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Vendor: LITE-ON
Product: COMBO SOHC-4832K Revision: O3K1 Serial
No:
Size: 0.00GB <0 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
TABLE 2-14
Options for prtdiag
Option
Description
How It Can Help
No option
Lists components.
Identifies CPU timing and PCI
cards installed.
-v
Verbose mode. Displays the time of the most recent AC
power failure, the most recent hardware fatal error
information, and (if applicable) environmental condition.
Provides the same information as
no option. Additionally lists fan
status, temperatures, ASIC, and
PROM revisions.