Chapter 11

XSCF Unit Replacement

11-5

11.2

Active Replacement and Hot
Replacement

Note –

To replace the XSCF Unit, you must consider the version of the XCP that is

currently in the server.

To determine the firmware version of the server, type:

For more information, refer to the

version

(8) man page or the SPARC Enterprise

M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference Manual.

If the version of XCP in your server is XCP 1041 or earlier, see

Appendix E

. If the

server has XCP1050 or later, follow the procedure described below.

The active replacement procedure and hot replacement procedure for the XSCFU are
the same.

The procedure is as follows.

1. Unlock and open a door of the server.

For details, see

Chapter 5

.

2. When the Active LED (green) of the XSCFU to be replaced is lit, log in to the

XSCF from a terminal connected to the XSCF, and then execute the switchscf
command for switching to Standby.

3. Use the maintenance menu to select the XSCFU to be replaced. (The

maintenance menu is used up to

Step 9

.)

The fieldeng permission is required for executing this command.

a. From the console that is connected to the Active XSCF, log in to the XSCF,

and execute the replacefru command.

As shown in

FIGURE 11-4

, the initial page of the maintenance menu is displayed.

XSCF> version -c xcp

XSCF> switchscf -t Standby