Chapter 19

DDC Replacement

19-3

19.2

Active Replacement and Hot
Replacement

The active replacement procedure and hot replacement procedure for the DDC are
the same.

The procedure is as follows.

1. Unlock and open the appropriate door of the server.

For details, see

Chapter 5

.

2. Using the maintenance menu, select the DDC to be replaced. (Use the

maintenance menu for

Step 7

.)

The fieldeng permission is required for executing this command.

a. Log in to the XSCF from the terminal connected to the XSCF, and execute the

replacefru

command.

The initial page of the maintenance menu is displayed as shown in

FIGURE 19-2

.

FIGURE 19-2

Initial Page of the Maintenance Menu

Note –

DDC_A is displayed only for the M8000.

b. Select "5. DDC" from the replacement parts list in the maintenance menu.

---------------------------------------------------

Maintenance/Replacement Menu

Please select a type of FRU to be replaced.

1. CMU/IOU(CPU Memory Board Unit/IO Unit)

2. FAN(Fan Unit)

3. PSU(Power Supply Unit)

4. XSCFU(Extended System Control Facility Unit)

5. DDC_A(DDC for BP_A)

---------------------------------------------------

Select [1-5|c:cancel] :