beautypg.com

2 configuring a pci card, 4 confirming the hardware, Configuring a pci card – FUJITSU SPARC ENTERPRISE M8000 User Manual

Page 101: Confirming the hardware

background image

Chapter 4

FRU Removal Preparation

4-7

1. Configuring into a domain

To configure CMU or IOU into the domain, enter the following command from
the terminal that is connected to the XSCF:

The system administrator permission is required for executing this command.

2. Checking resources

Log in to the XSCF and execute the showboard command to verify that the target
CMU or IOU has been correctly configured.

4.2.3.2

Configuring a PCI card

1. From the Solaris OS, use the cfgadm command to configure and connect the

component to the domain:

where AP_ID is the IOU and PCI card as shown in the output of cfgadm.

2. Use the cfgadm command to confirm the component is now connected and

configured:

4.2.4

Confirming the Hardware

1. Confirm that the replacement components are normal by using the

showhardconf

or showstatus command of XSCF.

Unless "*" is displayed for a replacement CMU, CPU, or DIMM, it is operating
normally.

XSCF> addboard -c configure

-d 0 00-0

# cfgadm -c configure AP_ID

# cfgadm

AP_ID

Type

Receptacle

Occupant

Condition

..

iou#0-pci#1

unknown

empty

unconfigured

unknown

iou#0-pci#2

unknown

empty

unconfigured

unknown

iou#0-pci#3

etherne/hp

connected

configured

ok

iou#0-pci#4

fibre/hp

connected

configured

ok