15-6

SPARC Enterprise M8000/M9000 Servers Service Manual • August 2009

8. From the OS, execute the cfgadm -a command to verify that the status of tape

drive unit and CD-RW/DVD-RW drive unit has changed from "configured" to
"unconfigured."

9. Detach the target tape drive unit from the port.

From the terminal that is connected to XSCF, log in to XSCF, and execute the
cfgdevice -c detach -p

port no. command.

10. Confirm that the target tape drive unit is unconfigured from the domain.

From XSCF, execute cfgdevice -l to confirm that the relevant port is not
displayed in the current connection.

11. Connect the wrist strap clip to a cabinet grounding port, and attach the band of

the wrist strap to one of your wrists.

12. Remove the tape drive unit to be replaced.

a. Using a Phillips screwdriver, loosen the two knob screws securing the tape

drive unit to be replaced.

b. While grasping the knob screws, pull out the tape drive unit slowly from the

slot.

# cfgadm -a

Ap_Id

Type

Receptacle

Occupant

Condition

:

c0::dsk/c0t4d0

CD-ROM connected

unconfigured

unknown

c0::rmt/0

tape

connected

unconfigured

unknown

: