FUJITSU SPARC ENTERPRISE M8000 User Manual
Page 314

15-6
SPARC Enterprise M8000/M9000 Servers Service Manual • August 2009
8. From the OS, execute the cfgadm -a command to verify that the status of tape
drive unit and CD-RW/DVD-RW drive unit has changed from "configured" to
"unconfigured."
9. Detach the target tape drive unit from the port.
From the terminal that is connected to XSCF, log in to XSCF, and execute the
cfgdevice -c detach -p
port no. command.
10. Confirm that the target tape drive unit is unconfigured from the domain.
From XSCF, execute cfgdevice -l to confirm that the relevant port is not
displayed in the current connection.
11. Connect the wrist strap clip to a cabinet grounding port, and attach the band of
the wrist strap to one of your wrists.
12. Remove the tape drive unit to be replaced.
a. Using a Phillips screwdriver, loosen the two knob screws securing the tape
drive unit to be replaced.
b. While grasping the knob screws, pull out the tape drive unit slowly from the
slot.
# cfgadm -a
Ap_Id
Type
Receptacle
Occupant
Condition
:
c0::dsk/c0t4d0
CD-ROM connected
unconfigured
unknown
c0::rmt/0
tape
connected
unconfigured
unknown
: