2 deletion, 2 addition and deletion of power cabinet, Deletion – FUJITSU SPARC ENTERPRISE M8000 User Manual

Page 426: Addition and deletion of power cabinet

background image

24-12

SPARC Enterprise M8000/M9000 Servers Service Manual • August 2009

From a console that is connected to XSCF, execute the poweron -a command
of XSCF.

The power to all the domains is turned on, and then the power-on self test (POST)
is executed. When ok prompt displayed on the console of relevant domain, POST
is completed.

For details of the power-on operation, see

Section 4.4.2, “Powering the Server On”

on page 4-19

, and the SPARC Enterprise M3000/M4000/M5000/M8000/M9000

Servers XSCF User’s Guide.

13. Confirm that the replacement components are normal by using the

showhardconf

or showstatus command of XSCF.

Unless "*" is displayed for the replacement RDPF, it is operating normally.

For details of the showhardconf command and showstatus command, see the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide,
the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference
Manual
, or the man page.

Note –

The showstatus command displays information on degraded components.

14. Restore the original mode switch setting on the operator panel.

Note –

Unless the mode switch is set to Locked when the maintenance work is

completed, the error notification function is disabled. Be sure to restore and confirm
the switch setting when the work is completed.

15. Close the door on the server, and lock it.

24.1.2.2

Deletion

Follow the addition instructions in reverse order.

24.2

Addition and Deletion of Power Cabinet

The three procedures listed below can be used. Regardless of the procedure used, see
the power cabinet installation procedure explained in the SPARC Enterprise
M8000/M9000 Servers Installation Guide
.

Adding or deleting a power cabinet for the SPARC Enterprise M8000 server with
three-phase dual power feed configured