SPARC Enterprise M8000/M9000 Servers Service Manual • August 2009

4.7.1.3

For Server Using Three-phase Power Feed

Note –

The server using three-phase power feed does not have any cable holder. In

this case, fasten the cables by running the hook-and-loop fastener through the slit
between the bracket at the cable holder mounting location and a column in the
cabinet. (

FIGURE 4-13

shows the fastening location on the left route.)

FIGURE 4-13

Cable Routing of the Server Using Three-Phase Power Feed

6. Fasten the cables running along the left route to the cable holder with a long

hook-and-loop fastener. (See (4) in

FIGURE 4-14

.)

7. Allow 12 cables of all the cables running along the right route to hang along

the right frame. (See (5) in

FIGURE 4-14

.)

8. Run the remaining cables from the right side to the left side while taking care

to prevent the cables from blocking the ventilation slits. (See (6) in

FIGURE 4-14

.)

Note –

Fujitsu recommends running the cables above the handle of the FAN unit.

9. Fasten 24 cables with a short hook-and-loop fastener to the handle of the fan

shelf. (See (7) in

FIGURE 4-14

.)

Location for Attaching a Hook-and-loop Fastener

Attached Hook-and-loop Fastener

Column of cabinet

Cable holder

mounting bracket

Hook-and-loop fastener