beautypg.com

FUJITSU SPARC ENTERPRISE M8000 User Manual

Page 342

background image

18-6

SPARC Enterprise M8000/M9000 Servers Service Manual • August 2009

Caution –

After stopping all the domains, be sure to switch off the main line

switches in the power supply system to completely shut off the supply of power.

6. Connect the wrist strap clip to a cabinet grounding port, and attach the band of

the wrist strap to one of your wrists.

7. Remove the ACS to be replaced. This section explains the ACS used for

single-phase power feed in the standard configuration.

M8000 (See

FIGURE 18-4

):

a. Using a Phillips screwdriver, loosen the thumb screw to remove the

connector protecting plate.

b. Loosen the connector retaining screws to disconnect three power cords.

c. Using a Phillips screwdriver, loosen the two thumb screws in the upper part

of the ACS.

Pull up the two levers to the open position.

d. Move the eject lever left to the open position.

e. While grasping the handle, pull out the ACS carefully from the slot.

M9000 (See

FIGURE 18-5

):

a. Loosen the cable support plate retaining screw, and remove the plate by

sliding it to the left.

b. Using a Phillips screwdriver, loosen the two thumb screws to remove the

connector protecting plate.

c. Using a Phillips screwdriver, loosen the connector retaining screws to

disconnect five power cords.

d. Move the eject lever up to the open position.

e. Using a Phillips screwdriver, loosen the two thumb screws in the upper part

of the ACS.

Pull up the two levers to the open position.

f. While grasping the handle, pull out the ACS carefully from the slot.

For three-phase AC section:

a. Unlock and open the door of the power cabinet.

b. Loosen the four screws on the ACS cover, and remove the ACS cover. (See

FIGURE 18-6

)