2 active replacement and hot replacement, Active replacement and hot replacement – FUJITSU SPARC ENTERPRISE M8000 User Manual

Page 238

background image

9-8

SPARC Enterprise M8000/M9000 Servers Service Manual • August 2009

9.2

Active Replacement and Hot
Replacement

Caution –

Each cabinet contains multiple PSUs so that the power output

specifications are satisfied even if one PSU fails. However, avoid continuing
operation for a long period with a faulty PSU left in the cabinet.

The active replacement procedure and hot replacement procedure for the PSUs are
the same.

The procedure is as follows.

1. Unlock and open a door of the server.

For details, see

Chapter 5

.

2. Display the maintenance menu, and select the swap target PSU. (The

maintenance menu is used up to

Step 8

.)

The fieldeng permission is required for executing this command.

a. From the console that is connected to XSCF, log in to XSCF, and execute the

replacefru

command.

As shown in

FIGURE 9-7

, the initial page of the maintenance menu is displayed.

FIGURE 9-7

Initial Page of the Maintenance Menu

Note –

DDC_A is displayed only for the M8000.

b. From the replacement parts list on the maintenance menu, select 3, "PSU."

---------------------------------------------------

Maintenance/Replacement Menu

Please select a type of FRU to be replaced.

1. CMU/IOU(CPU Memory Board Unit/IO Unit)

2. FAN(Fan Unit)

3. PSU(Power Supply Unit)

4. XSCFU(Extended System Control Facility Unit)

5. DDC_A(DDC for BP_A)

---------------------------------------------------

Select [1-5|c:cancel] :