Chapter 13

PCI Slot Device Replacement 13-15

b. If the lever stops halfway even when the PCI cassette is inserted again, pull

the PCI cassette out from the IOU, and then check whether the PCI card is
set in the normal position (see a, b, and c of

Step 10

). Then, reinsert the PCI

cassette.

Caution –

Do not forcibly push the lever of the PCI cassette when the lever is

pushed but stops halfway. In this case, restore the lever to its original position, and
then reinsert it. If the lever stops halfway even when the PCI cassette is inserted
again, it is possible that the PCI card is not set in the normal position (see a, b, and c
of

Step 10

). Pull the PCI cassette out from the IOU, verify the position of the PCI

card, and then reinsert the PCI cassette.

12. From the OS, execute the cfgadm -c connect <

PCI_ApId> command to

supply power to the PCI card.

13. From the OS, execute the cfgadm -c configure <

PCI_ApId> command to

configure the PCI card into the domain.

14. From the OS, execute the cfgadm -a command to confirm that the status of the

PCI card has changed from "unconfigured" to "configured."

15. Confirm that the replacement components are normal by using the

showhardconf

or showstatus command of XSCF.

Unless "*" is displayed for the replacement XSCFU, it is operating normally.

For details of the showhardconf command and showstatus command, see the
SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide,
the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference
Manual
, or the man page.

Note –

The showstatus command displays information on degraded components.

16. Close the door on the server and lock it.

# cfgadm -c connect iou#0_pci#3

# cfgadm -c configure iou#0_pci#3

# cfgadm -a

Ap_Id Type Receptacle Occupant Condition

:

iou#0_pci#3 pci_pci/hp connected

configured

ok