Figure 23-5 – FUJITSU SPARC ENTERPRISE M8000 User Manual

Page 412

background image

23-8

SPARC Enterprise M8000/M9000 Servers Service Manual • August 2009

FIGURE 23-5

Removing the SWBP (Front of the M9000)

9. Place the removed SWBP on an antistatic conductive mat.

10. Mount the replacement SWBP by following the removal instructions in

Step 7

and

Step 8

in reverse order.

Caution –

Do not forcibly push the SWBP in when inserting it. If the SWBP is

forcibly inserted despite the presence of any obstruction in a slot or any problems
with the connector pin, serious damage may result.
The connector on the left edge of the base plate of the switch BP is not used for the
SPARC Enterprise M8000 server. Be aware of this when connecting cables.

11. Switch on all main line switches for the AC section (ACS) in the power supply

system.

12. Confirm that the XSCF STANDBY LED (green) on the operator panel remains

lit. If it is blinking, wait until it remains lit.