Diagnostics

Profile LVS Event Management System Instruction Manual

9-29

Press STOP to terminate the test.

Press 0 return to the Main menu.

Press 3 when the Main menu is displayed on the LCDs. The following menu will
appear.

[KEY/LED TEST] SHIFT+0: Return to menu

,JOG/SHTL: Testing one by one.

The following two ways are used to execute key and LED functions.

H When you turn the JOG/SHTL knob, a lamp on the key lights on and then

off. Turn the knob until you confirm all the lamps and LEDs can light on and
off properly.

This test only verifies that the lamps and LEDs work properly. To verify that
the key functions properly, perform the following test.

H When you press a key, the corresponding lamp goes on and, when you press

that key again, the lamp goes off. Press all keys twice to confirm that the
keys work properly and that the lamps and LEDs function properly.

CAUTION. Prolonged lighting of all the key LEDs may heat the surface of the
Live Controller enough to cause personal injury. To avoid personal injury, you
should avoid lighting all the LEDs for more than ten minutes at a time. After ten
minutes of continuous operation, you should turn all the LEDs off for at least
five minutes before turning them on again.

Use the preceding test to confirm that all the keys, lamps and LEDs work
properly.

Press and hold SHIFT and press 0 to stop the test.

Key and LED Test