Starting the adjustment – Grass Valley LVS 100 v.3.15 User Manual
Page 283

Lever Adjustment
Profile LVS Event Management System Instruction Manual
8-3
Starting the Adjustment
Turn power on while holding the
A and " buttons. The following menu will
appear on both upper and lower LCDs of the Live Controller.
**** LEVER ADJUST ****
CONT: Starting calibration.
0: Starting up thesystem.
The letters to the left of the colon (:) indicate a key on the panel that you can
press to select and to advance the adjustment procedure. LCDs also light to
indicate that these keys are available for use.
NOTE. When the key configuration is being set to Alternate, the EVENT key
instead of the 0 key will light when you enter the lever adjustment routine. For
more detail about the Other key configuration, refer to About Key Configuration
on page 7–5.
Pressing 0 exits the lever adjustment routine and starts the Live Controller.
When you want to continue the adjustment procedures, press CONT. The
following messages appears.
[STEP 1]
1. Turn on the lever switch.
2. Move lever to position MAX FWD.
3. Push CONT key.
The messages displayed on the LCDs represent the adjustment procedures you
should follow.