Fuse Type and Rating

The Live Controller uses one of two fuses, depending on the country of use. The
U.S. and International fuse is installed in the fuse holder, while the other is
included in a bag labeled For Use in Canada Only. Table 7–1 lists the fuse
types and ratings.

Table 7-1: Fuse Type and Rating

Country of Use

Fuse

Fuse Part Number

U.S. and International

except Canada

5 mm

×

20 mm (IEC 127): 2A(T),250V

159Ć0107-00

Canada only

5 mm

×

20 mm

(UL 198G): 2A FAST,250V

159Ć0260Ć00

WARNING. To avoid electrical shock, always unplug the power cord from the
socket before checking the line fuse.

To check the fuse, remove the fuse holder on the rear panel. Refer to Figure 7–1
for the location of the fuse holder. To remove the fuse holder, use a flat-bladed
screwdriver to pull the fuse holder out. See Figure 9–12 on page 9–22. Then
remove the fuse from the fuse holder.

Applying and Interrupting Power

Observe the following when you power on the Live Controller.

At power-on, no self-test is provided to the Live Controller. Instead, LCD
backlights come on and the following message appears:

**** FAIL ****

Sony/Tektronix

X.XX

Where X.XX indicates the firmware version installed.

Key lamps and LEDs on the panel then light on and off in the following order:

PowerĆon Cycle