Table 9-2: Internal Inspection Check List

Item

InspectFor

Repair Action

Circuit boards

Loose, broken, or corroded

solder connections; burned circuit

boards; burned, broken, or

cracked circuitĆrun plating

Remove defective modules and

replace with a new module.

Modules

Dents, deformations, and damĆ

aged hardware

Replace module.

Cleaning Procedure Ċ Interior. If, after doing steps 1 and 3, a module is clean
upon inspection, skip the remaining steps.

1. Access parts to be cleaned by removing easily accessible shields and panels

(see Removal and Installation in this section).

2. Blow off dust with dry, low-pressure, deionized air (approximately 9 psi).

3. Remove any remaining dust with a lint-free cloth dampened in isopropyl

alcohol (75% solution), and rinse with warm deionized water. (A cotton-
tipped applicator is useful for cleaning in narrow spaces and on circuit
boards.)

4. Dry all parts with low-pressure, deionized air.

Lubrication. There is no periodic lubrication required for the Live Controller.