Maintenance
9-4
Profile LVS Event Management System Instruction Manual
Table 9-2: Internal Inspection Check List
Item
InspectFor
Repair Action
Circuit boards
Loose, broken, or corroded
solder connections; burned circuit
boards; burned, broken, or
cracked circuitĆrun plating
Remove defective modules and
replace with a new module.
Modules
Dents, deformations, and damĆ
aged hardware
Replace module.
Cleaning Procedure Ċ Interior. If, after doing steps 1 and 3, a module is clean
upon inspection, skip the remaining steps.
1. Access parts to be cleaned by removing easily accessible shields and panels
(see Removal and Installation in this section).
2. Blow off dust with dry, low-pressure, deionized air (approximately 9 psi).
3. Remove any remaining dust with a lint-free cloth dampened in isopropyl
alcohol (75% solution), and rinse with warm deionized water. (A cotton-
tipped applicator is useful for cleaning in narrow spaces and on circuit
boards.)
4. Dry all parts with low-pressure, deionized air.
Lubrication. There is no periodic lubrication required for the Live Controller.