2 to determine the input, 2 also sho, Three wire – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual

Page 89: Two wire

background image

Using the L Option

5-7

Figure 5.2
L Option Mode Selection and Typical TB3 Connections

1 See Speed Select table.

2 Drive must be stopped to take Local Control. Control by all other adapters is disabled (except Stop).

3 These inputs must be present before drive will start.

4 For Common Bus, this becomes Precharge Enable.

5 Bit 11 of Logic Options (parameter 17) must be 0 for reverse direction control.

6 For soft faults only. You need to recycle power to the drive to clear. For hard faults, refer to the Troubleshooting chapter.

7 To configure the stop type, refer to Logic Options (parameter 17).

8 This input must be present before the fault can be cleared and the drive will start. This can be disabled through Fault Select 2 (parameter 22)

and Warning Select 2 (parameter 23).

9 Latched starts require a stop to stop the drive. Note: This only affects the L Option stop. For modes that do not have Stop Type, stop commands

follow Stop 1 in Logic Options.

10 See Speed/Torque Select table. This takes precedence over Spd/Trq Mode Sel (parameter 68).

11 Unlatched (maintained) start.

12 In modes 5, 9, 10, and 15, the MOP value is not reset to 0 when you stop. In modes 27, 28, 29, and 30, the MOP value is reset to 0 when you stop.

NOTE: For detailed information on Modes 31 and 32 which were added for Speed Profiling applications, refer to page 9-23 in this manual.

19

20

21

22

23

24

25

26

27

28

29

30

Start

Not Stop , Clear Fault

Common

Not Ext Fault

Common

Speed Select 1

Common

Enable

Forward

Forward

Digital

Pot Dn

Forward

2nd

Accel

Jog

Speed

Select 3

Speed

Select 3

Digital

Pot Up

1st

Decel

Reverse Reverse

Digital

Pot Up

Reverse

1st

Accel

7

8

9

10

11

Mode

Speed

Select 2

Speed

Select 2

Speed

Select 2

Digital

Pot Dn

2nd

Decel

Speed/

Torque 2

Speed/

Torque 2

Forward

Speed/

Torque 2

Speed/

Torque 1

Speed/

Torque 1

Ramp

Disable

Speed/

Torque 1

Speed/

Torque 3

Speed/

Torque 3

Reverse

Speed/

Torque 3

19

20

21

22

Process

Trim

Flux

Enable

Reset

Speed

Select 2

Digital

Pot Dn

Forward

Speed

Select 3

Digital

Pot Up

Digital

Pot Up

Reverse

28

29

Speed

Select 2

Digital

Pot Dn

THREE WIRE

Run Forward

Not Stop , Clear Fault

Common

Run Reverse

Not Ext Fault

Common

Speed Select 2

Speed Select 1

Common

Enable

Local

Control

Stop

Type

2nd/1st

Accel

Digital

Pot Up

Local

Control

Speed

Select 3

Speed

Select 3

2nd/1st

Decel

Digital

Pot Dn

Stop
Type

12

13

14

15

16

Mode

19

20

21

22

23

24

25

26

27

28

29

30

Process

Trim

Flux

Enable

Process

Trim

Reset

Reset

Ramp

Disable

23

24

25

Jog

Speed

Select 3

26

Digital

Pot Up

Digital

Pot Dn

30

31 & 32
See Note Below

TWO WIRE

1

2

3

4

5

7

9

12

10

3

5

5

5

5

5

5

5

5

5

12

12

12

10

10

10

10

1

1

1

1

1

1

1

1

5,

3, 6

7

5, 11

4, 8

1

1

1

3

1

1

2

7

12

11

6

8

10

10

10

10

,

,