beautypg.com

Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual

Page 280

background image

11-82

Parameters

282

Step 12 Speed

Parameter 282 sets the rpm value for this step. (Scaling: 4096 =
Base Speed)

Parameter number

282

File:group

Profile Test Data

Parameter type

Setup

Display

+/- x.x rpm

Factory default

+0.00 rpm

Minimum value

-8 x base speed

Maximum value

+8 x base speed

Conversion

4096 = base sp

283

Step 12 Value

Parameter 283 sets the time in seconds for time steps, the
counts in units for encoder steps, and the TB3 input to trigger on
for TB Input steps. Scaling:

Time Step: 10 x desired value (10 = 1.0 sec)
Encoder Step: 10 = 1.0 units
TB Input Step: dependent on [L Option Mode Se Sel] See P241.

Parameter number

283

File:group

Profile Test Data

Parameter type

Setup

Display

x.xS, x, x.x units

Factory default

0.0,0, 0.0

Minimum value

0.0,0, 0.0

Maximum value

3276.7, 5, 3276.7

Conversion

10=1.0 sec., x TBin, 10 = 1 unit

284

Step 12 Type

Parameter 284 selects the type of step to be used

0 = Not Used (This forces an End Action)
1 = Time Step, operate at speed shown in P282 for time in P283.
2 = TB3 Input Step, operate at speed shown in P282 until this
input goes true.
3 = Encoder Step, operate at speed shown in P282 for units in
P283.

Parameter number

284

File:group

Profile Test Data

Parameter type

Setup

Display

x

Factory default

0

Minimum value

0

Maximum value

3

Conversion

285

Step 13 Speed

Parameter 285 sets the rpm value for this step. (Scaling: 4096 =
Base Speed)

Parameter number

285

File:group

Profile Test Data

Parameter type

Setup

Display

+/- x.x rpm

Factory default

+0.00 rpm

Minimum value

-8 x base speed

Maximum value

+8 x base speed

Conversion

4096 = base sp

286

Step 13 Value

Parameter 286 sets the time in seconds for time steps, the
counts in units for encoder steps, and the TB3 input to trigger on
for TB Input steps. Scaling:

Time Step: 10 x desired value (10 = 1.0 sec)
Encoder Step: 10 = 1.0 units
TB Input Step: dependent on [L Option Mode Sel]. See P241

Parameter number

286

File:group

Profile Test Data

Parameter type

Setup

Display

x.xS, x, x.x units

Factory default

0.0,0, 0.0

Minimum value

0.0,0, 0.0

Maximum value

3276.7, 5, 3276.7

Conversion

10=1.0 sec., x TBin, 10 = 1 unit

287

Step 13 Type

Parameter 287 selects the type of step to be used

0 = Not Used (This forces an End Action)
1 = Time Step, operate at speed shown in P285 for time in P286.
2 = TB3 Input Step, operate at speed shown in P285 until this
input goes true.
3 = Encoder Step, operate at speed shown in P285 for units in
P286.

Parameter number

287

File:group

Profile Test Data

Parameter type

Setup

Display

x

Factory default

0

Minimum value

0

Maximum value

3

Conversion