Page 280
11-82
Parameters
282
Step 12 Speed
Parameter 282 sets the rpm value for this step. (Scaling: 4096 =
Base Speed)
Parameter number
282
File:group
Profile Test Data
Parameter type
Setup
Display
+/- x.x rpm
Factory default
+0.00 rpm
Minimum value
-8 x base speed
Maximum value
+8 x base speed
Conversion
4096 = base sp
283
Step 12 Value
Parameter 283 sets the time in seconds for time steps, the
counts in units for encoder steps, and the TB3 input to trigger on
for TB Input steps. Scaling:
Time Step: 10 x desired value (10 = 1.0 sec)
Encoder Step: 10 = 1.0 units
TB Input Step: dependent on [L Option Mode Se Sel] See P241.
Parameter number
283
File:group
Profile Test Data
Parameter type
Setup
Display
x.xS, x, x.x units
Factory default
0.0,0, 0.0
Minimum value
0.0,0, 0.0
Maximum value
3276.7, 5, 3276.7
Conversion
10=1.0 sec., x TBin, 10 = 1 unit
284
Step 12 Type
Parameter 284 selects the type of step to be used
0 = Not Used (This forces an End Action)
1 = Time Step, operate at speed shown in P282 for time in P283.
2 = TB3 Input Step, operate at speed shown in P282 until this
input goes true.
3 = Encoder Step, operate at speed shown in P282 for units in
P283.
Parameter number
284
File:group
Profile Test Data
Parameter type
Setup
Display
x
Factory default
0
Minimum value
0
Maximum value
3
Conversion
285
Step 13 Speed
Parameter 285 sets the rpm value for this step. (Scaling: 4096 =
Base Speed)
Parameter number
285
File:group
Profile Test Data
Parameter type
Setup
Display
+/- x.x rpm
Factory default
+0.00 rpm
Minimum value
-8 x base speed
Maximum value
+8 x base speed
Conversion
4096 = base sp
286
Step 13 Value
Parameter 286 sets the time in seconds for time steps, the
counts in units for encoder steps, and the TB3 input to trigger on
for TB Input steps. Scaling:
Time Step: 10 x desired value (10 = 1.0 sec)
Encoder Step: 10 = 1.0 units
TB Input Step: dependent on [L Option Mode Sel]. See P241
Parameter number
286
File:group
Profile Test Data
Parameter type
Setup
Display
x.xS, x, x.x units
Factory default
0.0,0, 0.0
Minimum value
0.0,0, 0.0
Maximum value
3276.7, 5, 3276.7
Conversion
10=1.0 sec., x TBin, 10 = 1 unit
287
Step 13 Type
Parameter 287 selects the type of step to be used
0 = Not Used (This forces an End Action)
1 = Time Step, operate at speed shown in P285 for time in P286.
2 = TB3 Input Step, operate at speed shown in P285 until this
input goes true.
3 = Encoder Step, operate at speed shown in P285 for units in
P286.
Parameter number
287
File:group
Profile Test Data
Parameter type
Setup
Display
x
Factory default
0
Minimum value
0
Maximum value
3
Conversion