258 step 4 speed, 259 step 4 value, 260 step 4 type – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual
Page 276: 261 step 5 speed, 262 step 5 value, 263 step 5 type
![background image](/manuals/578736/276/background.png)
11-78
Parameters
258
Step 4 Speed
Parameter 258 sets the rpm value for this step. (Scaling: 4096 =
Base Speed)
Parameter number
258
File:group
Profile Test Data
Parameter type
Setup
Display
+/- x.x rpm
Factory default
+0.0 rpm
Minimum value
-8 x base speed
Maximum value
+8 x base speed
Conversion
4096 = Base Motor Speed
259
Step 4 Value
Parameter 259 sets the time in seconds for time steps, the
counts in units for encoder steps, and the TB3 input to trigger on
for TB Input steps. Scaling:
Time Step: 10 x desired value (10 = 1.0 sec)
Encoder Step: 10 = 1.0 units
TB Input Step: dependent on [L Option Mode Sel]. See P241.
Parameter number
259
File:group
Profile Test Data
Parameter type
Setup
Display
x.xS, x, x.x units
Factory default
0.0,0, 0.0
Minimum value
0.0,0, 0.0
Maximum value
3276.7, 5, 3276.7
Conversion
0=1.0 sec., x TBin, 10 = 1 unit
260
Step 4 Type
Parameter 260 selects the type of step to be used
0 = Not Used (This forces an End Action)
1 = Time Step, operate at speed shown in P258 for time in P259.
2 = TB3 Input Step, operate at speed shown in P258 until this
input goes true.
3 = Encoder Step, operate at speed shown in P258 for units in
P259.
Parameter number
260
File:group
Profile Test Data
Parameter type
Setup
Display
x
Factory default
0
Minimum value
0
Maximum value
3
Conversion
261
Step 5 Speed
Parameter 261 sets the rpm value for this step. (Scaling: 4096 =
Base Speed)
Parameter number
261
File:group
Profile Test Data
Parameter type
Setup
Display
+/- x.x rpm
Factory default
+0.0 rpm
Minimum value
-8 x base speed
Maximum value
+8 x base speed
Conversion
4096 = Base Motor Speed
262
Step 5 Value
Parameter 262 sets the time in seconds for time steps, the
counts in units for encoder steps, and the TB3 input to trigger on
for TB Input steps. Scaling:
Time Step: 10 x desired value (10 = 1.0 sec)
Encoder Step: 1 = 1 revolution
TB Input Step: dependent on [L Option Mode Sel]. See P241.
Parameter number
262
File:group
Profile Test Data
Parameter type
Setup
Display
x.xS, x, x.x units
Factory default
0.0,0, 0.0
Minimum value
0.0,0, 0.0
Maximum value
3276.7, 5, 3276.7
Conversion
0=1.0 sec., x TBin, 10 = 1 unit
263
Step 5 Type
Parameter 263 selects the type of step to be used
0 = Not Used (This forces an End Action)
1 = Time Step, operate at speed shown in P261 for time in P262.
2 = TB3 Input Step, operate at speed shown in P261 until P262
input goes true.
3 = Encoder Step, operate at speed shown in P261 for units in
P262.
Parameter number
263
File:group
Profile Test Data
Parameter type
Setup
Display
x
Factory default
0
Minimum value
0
Maximum value
3
Conversion