144 data in c1, 145 data in c2, 146 data in d1 – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual
Page 244: 147 data in d2, 148 data out a1, 149 data out a2
11-46
Parameters
144
Data In C1
Use Data In C1 to view the SCANport to drive image that is
received from some device on SCANport. This image may be
referred to as the SCANport I/O image or a datalink in the
manual for your communications module.
Parameter number
File:group
Interface/Comm:Gateway Data In
Parameter type
source
Display
±x
Factory default
not applicable
Minimum value
-32767
Maximum value
+32767
Conversion
1 = 1
145
Data In C2
Use Data In C2 to view the SCANport to drive image that is
received from some device on SCANport. This image may be
referred to as the SCANport I/O image or a datalink in the
manual for your communications module.
Parameter number
File:group
Interface/Comm:Gateway Data In
Parameter type
source
Display
±x
Factory default
not applicable
Minimum value
-32767
Maximum value
+32767
Conversion
1 = 1
146
Data In D1
Use Data In D1 to view the SCANport to drive image that is
received from some device on SCANport. This image may be
referred to as the SCANport I/O image or a datalink in the
manual for your communications module.
Parameter number
File:group
Interface/Comm:Gateway Data In
Parameter type
source
Display
±x
Factory default
not applicable
Minimum value
-32767
Maximum value
+32767
Conversion
1 = 1
147
Data In D2
Use Data In D2 to view the SCANport to drive image that is
received from some device on SCANport. This image may be
referred to as the SCANport I/O image or a datalink in the
manual for your communications module.
Parameter number
File:group
Interface/Comm:Gateway Data In
Parameter type
source
Display
±x
Factory default
not applicable
Minimum value
-32767
Maximum value
+32767
Conversion
1 = 1
148
Data Out A1
Use Data Out A1 to view the drive to SCANport image that is
sent to some device on SCANport. This image may be referred to
as the SCANport I/O image or a datalink in the manual for your
communications module.
Parameter number
File:group
Interface/Comm:Gateway Data Out
Parameter type
linkable destination
Display
±x
Factory default
+0
Minimum value
-32767
Maximum value
+32767
Conversion
1 = 1
149
Data Out A2
Use Data Out A2 to view the drive to SCANport image that is
sent to some device on SCANport. This image may be referred to
as the SCANport I/O image or a datalink in the manual for your
communications module.
Parameter number
File:group
Interface/Comm:Gateway Data Out
Parameter type
linkable destination
Display
±x
Factory default
+0
Minimum value
-32767
Maximum value
+32767
Conversion
1 = 1