229 int torque ref, 230 iq offset, 231 id offset – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual
Page 271: 232 function in9, 234 motor voltage
Parameters
11-73
229
Int Torque Ref
Int Torque Ref shows the value of torque reference that is present
at the output of the torque limiter.
1 Int Torque Ref was added in Version 3.xx.
Parameter number
File:group
Monitor: Motor Status
Parameter type
source
Display
±x.x%
Factory default
0.0%
Minimum value
-800%
Maximum value
+800%
Conversion
4096 = Rated Torque
230
IQ Offset contains the LEM U offset required to null the current
error (no motor current flowing). This offset is set automatically
by running the transistor diagnostics.
1 Iq Offset was added in Version 3.xx.
Parameter number
File:group
None
Parameter type
linkable destination
Display
±x
Factory default
0
Minimum value
-100
Maximum value
+100
Conversion
1 = 1
231
Id Offset contains the LEM W offset required to null the current
error (no motor current flowing). This offset is set automatically
by running the transistor diagnostics.
1 Id Offset was added in Version 3.xx.
Parameter number
File:group
None
Parameter type
linkable destination
Display
±x
Factory default
0
Minimum value
-100
Maximum value
+100
Conversion
1 = 1
232
Function In9
Use Function In9 to provide input to the function block that is
provided with the 1336 IMPACT drive.
1 Function In9 was added in Version 3.xx.
Parameter number
File:group
Application: Prog Function
Parameter type
sink
Display
±x
Factory default
0
Minimum value
-32767
Maximum value
+32767
Conversion
1 = 1
Refer to Chapter 10, Using the Function Block, for more
information.
233
Use Function In10 to provide input to the function block that is
provided with the 1336 IMPACT drive.
1 Function In10 was added in Version 3.xx.
Parameter number
File:group
Application: Prog Function
Parameter type
sink
Display
±x
Factory default
0
Minimum value
-32767
Maximum value
+32767
Conversion
1 = 1
Refer to Chapter 10, Using the Function Block, for more
information.
234
Motor Voltage %
Use Motor Voltage % to view the actual line-to-line fundamental
RMS value of motor voltage as a percentage. This data is
averaged and updated every 50 milliseconds.
1 Motor Voltage was added in Version 3.xx.
Parameter number
File:group
Monitor:Motor Status
Parameter type
source
Display
x.x%
Factory default
NA
Minimum value
0%
Maximum value
800%
Conversion
4096 = motor volts