95 test select 2 – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual
Page 230
11-32
Parameters
95
Test Select 2
Test Select 2 is a diagnostic tool that you can use to access
specific testpoints. The value you enter specifies which data
values should be displayed in Test Data 2 (parameter 94). For
Test Select 2 values of 11100 through 11232, you need to first
enter a 111xx value to determine the number of hours since
power up, and then enter a 112xx value to determine the number
of minutes and seconds since power up.
Parameter number
File:group
Monitor:Testpoints
Fault Setup:Testpoints
Parameter type
linkable destination
Display
x
Factory default
0
Minimum value
0
Maximum value
65535
Conversion
1 = 1
If you enter this value for
Test Select 2 (parameter 95):
Then, the value in Test Data 2 (parameter 94) represents the:
9728
Scaled version of Torque Ref 1 (parameter 69)
9730
Sum of scaled Torque Ref 1 (parameter 69) and PTrim Output (parameter 48)
9987
Upper current limit (4096 @ rated motor positive current)
9988
Lower current limit (-4096 @ rated motor negative current)
9990
Upper torque limit (4096 @ rated motor positive torque)
9991
Lower torque limit (-4096 @ rated motor negative torque)
10000
Motor Flux % (parameter 88) limited to Min Flux Level (parameter 71)
10264
Value of Logic Input Status (par 14) at the time of the last stop event.
10503
Parameter limit conditions
10504
Parameter limit conditions
10505
Speed reference math limits
10506
Speed feedback math limits
10507
Speed regulator math limits
10508
Torque reference math limits
10509
Process trim math limits
hours
minutes/seconds
11100
11200
Realtime accumulated since power up
11101
11201
The time since power up that the fault in position 1 occurred
11102
11202
The time since power up that the fault in position 2 occurred
11103
11203
The time since power up that the fault in position 3 occurred
11104
11204
The time since power up that the fault in position 4 occurred
11105
11205
The time since power up that the fault in position 5 occurred
11106
11206
The time since power up that the fault in position 6 occurred
11107
11207
The time since power up that the fault in position 7 occurred
11108
11208
The time since power up that the fault in position 8 occurred
11109
11209
The time since power up that the fault in position 9 occurred
11110
11210
The time since power up that the fault in position 10 occurred
11111
11211
The time since power up that the fault in position 11 occurred
11112
11212
The time since power up that the fault in position 12 occurred
11113
11213
The time since power up that the fault in position 13 occurred
11114
11214
The time since power up that the fault in position 14 occurred
11115
11215
The time since power up that the fault in position 15 occurred
11116
11216
The time since power up that the fault in position 16 occurred
11117
11217
The time since power up that the fault in position 17 occurred
11118
11218
The time since power up that the fault in position 18 occurred
11119
11219
The time since power up that the fault in position 19 occurred
11120
11220
The time since power up that the fault in position 20 occurred
11121
11221
The time since power up that the fault in position 21 occurred
11122
11222
The time since power up that the fault in position 22 occurred
11123
11223
The time since power up that the fault in position 23 occurred