11-64
Parameters
204
Function In3
Use Function In3 to provide input into the function block that is
provided with the 1336 IMPACT drive. You can choose to either
evaluate the input value or pass the value directly to the function
block.
To evaluate Function In3, you need to also use Func 3 Mask/Val
(parameter 205) and Func 3 Eval Sel (parameter 206).
To pass the value directly to the function block, enter a value of 0
into Func 3 Eval Sel.
1 Function In3 was added in Version 2.xx.
Parameter number
File:group
Application:Prog Function
Parameter type
linkable destination
Conversion
1 = 1
If Func 3 Eval Sel (parameter 206) is 0 or 6 – 11, then:
Display
±x
Factory default
0
Minimum value
-32767
Maximum value
+32767
If Func 3 Eval Sel (parameter 206) is 1 – 5, then:
Display
bits
Factory default
00000000.00000000
Minimum value
00000000.00000000
Maximum value
11111111.11111111
If Func 3 Eval Sel (parameter 206) is 12 – 15, then:
Display
x
Factory default
0
Minimum value
0
Maximum value
65535
Refer to Chapter 10, Using the Function Block, for more
information.
205
Func 3 Mask/Val
Use Func 3 Mask/Val to enter a mask or value to compare
Function In3 (parameter 204) to, according to the value you
select in Func 3 Eval Sel (parameter 206).
1 Func 3 Mask/Val was added in Version 2.xx.
Parameter number
File:group
Application:Prog Function
Parameter type
linkable destination
Conversion
1 = 1
If Func 3 Eval Sel (parameter 206) is 0 or 6 – 11, then:
Display
±x
Factory default
-1
Minimum value
-32767
Maximum value
+32767
If Func 3 Eval Sel (parameter 206) is 1 – 5, then:
Display
bits
Factory default
11111111.11111111
Minimum value
00000000.00000000
Maximum value
11111111.11111111
If Func 3 Eval Sel (parameter 206) is 12 – 15, then:
Display
x
Factory default
65535
Minimum value
0
Maximum value
65535
Refer to Chapter 10, Using the Function Block, for more
information.