270 step 8 speed, 271 step 8 value, 272 step 8 type – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual
Page 278: 273 step 9 speed, 274 step 9 value, 275 step 9 type

11-80
Parameters
270
Step 8 Speed
Parameter 270 sets the rpm value for this step. (Scaling: 4096 =
Base Speed)
Parameter number
270
File:group
Profile Test Data
Parameter type
Setup
Display
+/- x.x rpm
Factory default
+0.0 rpm
Minimum value
-8 x base speed
Maximum value
+8 x base speed
Conversion
4096 = Base Motor Speed
271
Step 8 Value
Parameter 271 sets the time in seconds for time steps, the
counts in units for encoder steps, and the TB3 input to trigger on
for TB Input steps. Scaling:
Time Step: 10 x desired value (10 = 1.0 sec)
Encoder Step: 10 = 1.0 units
TB Input Step: dependent on [L Option Mode Sel]. See P241
Parameter number
271
File:group
Profile Test Data
Parameter type
Setup
Display
x.xS, x, x.x units
Factory default
0.0,0, 0.0
Minimum value
0.0,0, 0.0
Maximum value
3276.7, 5, 3276.7
Conversion
10=1.0 sec., x TBin, 10 = 1 unit
272
Step 8 Type
Parameter 272 selects the type of step to be used
0 = Not Used (This forces an End Action)
1 = Time Step, operate at speed shown in P270 for time in P271.
2 = TB3 Input Step, operate at speed shown in P270 until this
input goes true.
3 = Encoder Step, operate at speed shown in P270 for units in
P271.
Parameter number
272
File:group
Profile Test Data
Parameter type
Setup
Display
x
Factory default
0
Minimum value
0
Maximum value
3
Conversion
273
Step 9 Speed
Parameter 273 sets the rpm value for this step. (Scaling: 4096 =
Base Speed)
Parameter number
273
File:group
Profile Test Data
Parameter type
Setup
Display
+/- x.x rpm
Factory default
+0.0 rpm
Minimum value
-8 x base speed
Maximum value
+8 x base speed
Conversion
4096 = Base Motor Speed
274
Step 9 Value
Parameter 274 sets the time in seconds for time steps, the
counts in units for encoder steps, and the TB3 input to trigger on
for TB Input steps. Scaling:
Time Step: 10 x desired value (10 = 1.0 sec)
Encoder Step: 10 = 1.0 units
TB Input Step: dependent on [L Option Mode Sel]. See P241
Parameter number
274
File:group
Profile Test Data
Parameter type
Setup
Display
x.xS, x, x.x units
Factory default
0.0,0, 0.0
Minimum value
0.0,0, 0.0
Maximum value
3276.7, 5, 3276.7
Conversion
10=1.0 sec., x TBib, 10 = 1 unit
275
Step 9 Type
Parameter 275 selects the type of step to be used
0 = Not Used (This forces an End Action)
1 = Time Step, operate at speed shown in P273 for time in P274.
2 = TB3 Input Step, operate at speed shown in P273 until this
input goes true.
3 = Encoder Step, operate at speed shown in P273 for units in
P274.
Parameter number
275
File:group
Profile Test Data
Parameter type
Setup
Display
x
Factory default
0
Minimum value
0
Maximum value
3
Conversion