Chapter

5

Using the L Option

Chapter Objectives

Chapter 5 provides information to help you set up and use the
L Option.

Important: If you are using an L Option board, you must wire the
L Option board before you start your drive.

If you do not have an L Option board installed, verify that two
jumpers are installed at connector J5 (for frames A1 – A4) or J2 (for
frames B – H), one at pins 3 and 4 and the other at pins 17 and 18.
You can skip the remainder of this chapter.

This topic:

Starts on page:

A description of the L Option

5-2

A list of the available functions

5-3

Setting up the L Option board

5-4

Using an encoder with the L Option board

5-11

Individual board requirements

5-11

L Option board
Connector

Language

Module

Jumper 1

Jumper 2

Spares

L Option
Connectors

Jumper 1

Jumper 2

Spares

Spare jumpers are located at J12 and J13 for Frames A1 – A4 and
J17 and J18 for Frames B – H.

!

ATTENTION: If you are using an L8E or L9E for the
encoder but do not want to use the L Option inputs, you
need to place jumpers on J5 (stop) and J6 (enable) on
the L Option board. However, these jumpers must not
be present if you use the L Option inputs as the jumpers
cause the stop and enable functions to be permanently
enabled.