Parameters

11-37

115

Relay Setpoint 1

Relay Setpoint 1 lets you specify the setpoint threshold for either
speed or current. Relay Setpoint 1 is only active if Relay Config 1
(parameter 114) is set to a value of 25, 26, 27, or 28.

Parameter number

115

File:group

Interface/Comm:Digital Config

Parameter type

linkable destination

Display

±x.x%

Factory default

+0.0%

Minimum value

-800.0%

Maximum value

+800.0%

Conversion

4096 = 100.0%

116

L Option Mode

Use L Option Mode to select the functions of L Option inputs at
TB3. If you change the value of L Option Mode, you must cycle
power before the change will take effect.

The following is the mode information:

Parameter number

116

File:group

Interface/Comm:Digital Config

Parameter type

destination

Display

x

Factory default

1

Minimum value

1

Maximum value

32

Conversion

1 = 1

Refer to Chapter 5, Using the L Option, for additional information.

Mode

TB3-19

TB3-20

TB3-22

TB3-23

1

Status

Stop

Status

Status

2

Start

Stop

Rev/Fwd

Jog

3

Start

Stop

Rev/Fwd

2/1Stop Type

4

Start

Stop

Rev/Fwd

2/1 Accel

5

Start

Stop

Rev/Fwd

Pot Up

6

Start

Stop

Rev/Fwd

Jog

7

Start

Stop

Rev

Fwd

8

Start

Stop

Rev

Fwd

9

Start

Stop

Pot Up

Pot Dn

10

Start

Stop

Rev

Fwd

11

Start

Stop

1st Accel

2nd Accel

12

Run Fwd

Stop

Run Rev

Loc/Rem

13

Run Fwd

Stop

Run Rev

2/1 Stop Type

14

Run Fwd

Stop

Run Rev

2/1 Accel

15

Run Fwd

Stop

Run Rev

Pot Up

16

Run Fwd

Stop

Run Rev

Loc/Rem

17

Start

Stop

Rev/Fwd

Proc Trim

18

Start

Stop

Rev/Fwd

Flux En

19

Start

Stop

Spd/Trq 3

Spd/Trq 2

20

Start

Stop

Spd/Trq 3

Spd/Trq 2

21

Start

Stop

Rev

Fwd

22

Start

Stop

Spd/Trq 3

Spd/Trq 2

23

Run Fwd

Stop

Run Rev

Proc Trim

24

Run Fwd

Stop

Run Rev

Flux En

25

Run Fwd

Stop

Run Rev

Proc Trim

26

1

Run Fwd

Stop

Run Rev

Jog

27

2

Start

Stop

Rev/Fwd

Pot Up

28

2

Start

Stop

Pot Up

Pot Dn

29

2

Start

Stop

Rev

Fwd

30

2

Run Fwd

Stop

Run Rev

Pot Up

31

3

Step Trigger Not Stop Step Trigger

Step Trigger

32

3

Start

Not Stop Step Trigger

Step Trigger

1 Added for Version 2.01.

2 Added for Version 2.02

3 Added for Version 4.01

TB3-24

TB3-26

TB3-27

TB3-28

Status

Status

Status

Status

Ext Fault

Spd 3

Spd 2

Spd 1

Ext Fault

Spd 3

Spd 2

Spd 1

Ext Fault

2/1 Decel

Spd 2

Spd 1

Ext Fault

Pot Dn

Spd 2

Spd 1

Ext Fault

Loc/Rem

Spd 2

Spd 1

Ext Fault

Jog

Spd 2

Spd 1

Ext Fault

Spd 3

Spd 2

Spd 1

Ext Fault

Spd 3

Spd 2

Spd 1

Ext Fault

Pot Up

Pot Dn

Spd 1

Ext Fault

1st Decel

2nd Decel

Spd 1

Ext Fault

Spd 3

Spd 2

Spd 1

Ext Fault

Spd 3

Spd 2

Spd 1

Ext Fault

2/1 Decel

Spd 2

Spd 1

Ext Fault

Pot Dn

Spd 2

Spd 1

Ext Fault

2/1 Stop Type Spd 2

Spd 1

Ext Fault

Ramp

Spd 2

Spd 1

Ext Fault

Reset

Spd 2

Spd 1

Ext Fault

Spd/Trq 1

Proc Trim

Spd 1

Ext Fault

Spd/Trq 1

Flux En

Spd 1

Ext Fault

Ramp

Reset

Spd 1

Ext Fault

Spd/Trq 1

Spd 2

Spd 1

Ext Fault

Reset

Spd 2

Spd 1

Ext Fault

Reset

Spd 2

Spd 1

Ext Fault

Ramp

Spd 2

Spd 1

Ext Fault

Spd 3

Spd 2

Spd 1

Ext Fault

Pot Dn

Spd 2

Spd 1

Ext Fault

Spd 3

Spd 2

Spd 1

Ext Fault

Pot Up

Pot Dn

Spd 1

Ext Fault

Pot Dn

Spd 2

Spd 1

Not Ext Flt

Step Trigger

Step Trigger

Step Trigger

Not Ext Flt

Profile Enable Run SequenceStep Hold