Parameters
180
Freq Track Filtr
Freq Track Filtr contains the rotor frequency regulator filter in
encoderless mode. Do not change the value of this parameter.
Parameter number
File:group
none
Parameter type
destination
Display
x
Factory default
5000
Minimum value
0
Maximum value
32767
Conversion
1 = 1
181
SP 2 Wire Enable
SP 2 Wire Enable lets you specify whether the specified
SCANport device uses 2 wire or 3 wire control. When you are
operating in 2 wire control, the start button acts like a jog.
1 SP 2 Wire Enable was added in Version 2.xx.
Parameter number
File:group
Interface/Comm:SCANport Config
Parameter type
destination
Display
bits
Factory default
00000000
Minimum value
00000000
Maximum value
11111110
Conversion
1 = 1
Bit
Description
0
Reserved
Leave 0.
1
SP 1
Set to enable the device connected to SCANport 1 for
2 wire control.
2
SP 2
Set to enable the device connected to SCANport 2 for
2 wire control.
3
SP 3
Set to enable the device connected to SCANport 3 for
2 wire control.
Bit
Description
4
SP 4
Set to enable the device connected to SCANport 4 for
2 wire control.
5
SP 5
Set to enable the device connected to SCANport 5 for
2 wire control.
6
SP 6
Set to enable the device connected to SCANport 6 for
2 wire control.
7
P197
Set to enable Logic Cmd Input (parameter 197) for 2
wire control.
182
Use An In1 Filter BW to use a low pass filter on the analog
input 1. This filter adjusts the bandwidth to get better filtering. By
using the low pass filter, you lose some bandwidth, but the value
becomes more stable.
1 An In1 Filter BW was added in Version 2.xx.
Parameter number
File:group
Interface/Comm:Analog Inputs
Parameter type
linkable destination
Display
x.x radians per second
Factory default
0.0 radians per second
Minimum value
0.0 radians per second
Maximum value
200.0 radians per second
Conversion
10 = 1
183
Use An In2 Filter BW to use a low pass filter on the analog
input 2. This filter adjusts the bandwidth to get better filtering. By
using the low pass filter, you lose some bandwidth, but the value
becomes more stable.
1 An In1 Filter BW was added in Version 2.xx.
Parameter number
File:group
Interface/Comm:Analog Inputs
Parameter type
linkable destination
Display
x.x radians per second
Factory default
0.0 radians per second
Minimum value
0.0 radians per second
Maximum value
200.0 radians per second
Conversion
10 = 1
184
mA In Filter BW
Use mA In Filter BW to use a low pass filter on the 4 – 20 mA
input. This filter adjusts the bandwidth to get better filtering. By
using the low pass filter, you lose some bandwidth, but the value
becomes more stable.
1 mA In Filter BW was added in Version 2.xx.
Parameter number
File:group
Interface/Comm:Analog Inputs
Parameter type
linkable destination
Display
x.x radians per second
Factory default
0.0 radians per second
Minimum value
0.0 radians per second
Maximum value
200.0 radians per second