264 step 6 speed, 265 step 6 value, 266 step 6 type – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual
Page 277: 267 step 7 speed, 268 step 7 value, 269 step 7 type
Parameters
11-79
264
Step 6 Speed
Parameter 264 sets the rpm value for this step. (Scaling: 4096 =
Base Speed)
Parameter number
264
File:group
Profile Test Data
Parameter type
Setup
Display
+/- x.x rpm
Factory default
+0.0 rpm
Minimum value
-8 x base speed
Maximum value
+8 x base speed
Conversion
4096 = Base Motor Speed
265
Step 6 Value
Parameter 265 sets the time in seconds for time steps, the
counts in units for encoder steps, and the TB3 input to trigger on
for TB Input steps. Scaling:
Time Step: 10 x desired value (10 = 1.0 sec)
Encoder Step: 10 = 1.0 units
TB Input Step: dependent on [L Option Mode Sel]. See P241
Parameter number
265
File:group
Profile Test Data
Parameter type
Setup
Display
x.xS, x, x.x units
Factory default
0.0,0, 0.0
Minimum value
0.0,0, 0.0
Maximum value
3276.7, 5, 3276.7
Conversion
0=1.0 sec., x TBin, 10 = 1 unit
266
Step 6 Type
Parameter 266 selects the type of step to be used
0 = Not Used (This forces an End Action)
1 = Time Step, operate at speed shown in P264 for time in P265.
2 = TB3 Input Step, operate at speed shown in P264 until this
input goes true.
3 = Encoder Step, operate at speed shown in P264 for units in
P265.
Parameter number
266
File:group
Profile Test Data
Parameter type
Setup
Display
x
Factory default
0
Minimum value
0
Maximum value
3
Conversion
267
Step 7 Speed
Parameter 267 sets the rpm value for this step. (Scaling: 4096 =
Base Speed)
Parameter number
267
File:group
Profile Test Data
Parameter type
Setup
Display
+/- x.x rpm
Factory default
+0.0 rpm
Minimum value
-8 x base speed
Maximum value
+8 x base speed
Conversion
4096 = Base Motor Speed
268
Step 7 Value
Parameter 268 sets the time in seconds for time steps, the
counts in units for encoder steps, and the TB3 input to trigger on
for TB Input steps. Scaling:
Time Step: 10 x desired value (10 = 1.0 sec)
Encoder Step: 10 = 1.0 units
TB Input Step: dependent on [L Option Mode Sel] See P241.
Parameter number
268
File:group
Profile Test Data
Parameter type
Setup
Display
x.xS, x, x.x units
Factory default
0.0,0, 0.0
Minimum value
0.0,0, 0.0
Maximum value
3276.7, 5, 3276.7
Conversion
10=1.0 sec., x TBin, 10 = 1 unit
269
Step 7 Type
Parameter 269 selects the type of step to be used
0 = Not Used (This forces an End Action)
1 = Time Step, operate at speed shown in P267 for time in P268.
2 = TB3 Input Step, operate at speed shown in P267 until this
input goes true.
3 = Encoder Step, operate at speed shown in P267 for units in
P268.
Parameter number
269
File:group
Profile Test Data
Parameter type
Setup
Display
x
Factory default
0
Minimum value
0
Maximum value
3
Conversion