Parameters
21
Warning Select 1
Use Warning Select 1 to specify how the drive should handle
certain conditions. Each bit within this parameter matches the bit
definitions of Fault Select 1 (parameter 20). If you set a bit to 1
and the corresponding bit in Fault Select 1 is clear (0), the drive
reports a warning when that condition occurs. If both
corresponding bits in Fault Select 1 and Warning Select 1 are 0,
the drive ignores the condition when it occurs.
The bits are defined as follows:
Parameter number
File:group
Fault Setup:Fault Config
Parameter type
linkable destination
Display
bits
Factory default
00000000.00011100
Minimum value
00000000.00000000
Maximum value
01111111.00111111
Conversion
1 = 1
Refer to Chapter 12, Troubleshooting, for additional information.
Bit
Description
0
RidethruTime
A bus ridethrough timeout
occurred.
1
Prechrg Time
A bus precharge timeout
occurred.
2
Bus Drop
A bus drop of 150 volts occurred.
3
Bus Undervlt
A bus undervoltage occurred.
4
Bus Cycles>5
More than 5 ridethroughs
occurred in a row.
5
Open Circuit
Fast flux up current is <50%.
Bit
Description
6 – 7
Reserved
Leave 0.
8
mA Input
A loss of input connection
occurred after it was established.
9
SP 1 Timeout
Loss of communication with
SCANport device 1 occurred.
10
SP 2 Timeout
Loss of communication with
SCANport device 2 occurred.
11
SP 3 Timeout
Loss of communication with
SCANport device 3 occurred.
Bit
Description
12
SP 4 Timeout
Loss of communication with
SCANport device 4 occurred.
13
SP 5 Timeout
Loss of communication with
SCANport device 5 occurred.
14
SP 6 Timeout
Loss of communication with
SCANport device 6 occurred.
15
SP Error
Too many errors on the
SCANport communication.
22
Fault Select 2
Use Fault Select 2 to specify how the drive should handle certain
conditions. Each bit matches the bit definitions of Warning
Select 2 (parameter 23). If you set a bit to 1, the drive reports a
fault when that condition occurs. If you clear a bit to 0, the drive
reports the condition based on Warning Select 2.
The bits are defined as follows:
Parameter number
File:group
Fault Setup:Fault Config
Parameter type
linkable destination
Display
bits
Factory default
10000000.00010001
Minimum value
00000000.00000000
Maximum value
11111111.11111111
Conversion
1 = 1
Refer to Chapter 12, Troubleshooting, for additional information.
Bit
Description
0
SpdFdbk Loss
A loss of feedback occurred.
1
InvOvtmp Pnd
An inverter overtemp is pending.
2
Reserved
Leave 0.
3
MtrOvld Pend
A motor overload is pending (I
2
T).
4
MtrOvld Trip
Motor overload trip (I
2
T)
Bit
Description
5
Mtr Stall
The motor stalled.
6
Ext Fault In
The ext input is open.
7 – 8
Reserved
Leave 0.
9
Param Limit
A parameter is out of limits
10
Math Limit
A math limit occurred.
Bit
Description
11 – 12 Reserved
Leave 0.
13
InvOvld Pend
An inverter overload is pending
(IT).
14
Reserved
Leave 0.
15
InvOvld Trip
Inverter overload trip (IT)