Parameters

11-83

288

Step 14 Speed

Parameter 288 sets the rpm value for this step. (Scaling: 4096 =
Base Speed)

Parameter number

288

File:group

Profile Test Data

Parameter type

Setup

Display

+/- x.x rpm

Factory default

+0.0 rpm

Minimum value

-8 x base sp

Maximum value

+8 x base sp

Conversion

4096 = base sp

289

Step 14 Value

Parameter 289 sets the time in seconds for time steps, the
counts in units for encoder steps, and the TB3 input to trigger on
for TB Input steps. Scaling:

Time Step: 10 x desired value (10 = 1.0 sec)
Encoder Step: 10 = 1.0 units
TB Input Step: dependent on [L Option Mode Sel]. See P241

Parameter number

289

File:group

Profile Test Data

Parameter type

Setup

Display

x.xS, x, x.x units

Factory default

0.0,0, 0.0

Minimum value

0.0,0, 0.0

Maximum value

3276.7, 5, 3276.7

Conversion

10=1.0 sec., x TBin, 10 = 1 unit

290

Step 14 Type

Parameter 290 selects the type of step to be used

0 = Not Used (This forces an End Action)
1 = Time Step, operate at speed shown in P288 for time in P289.
2 = TB3 Input Step, operate at speed shown in P288 until this
input goes true.
3 = Encoder Step, operate at speed shown in P288 for units in
P289.

Parameter number

290

File:group

Profile Test Data

Parameter type

Setup

Display

x

Factory default

0

Minimum value

0

Maximum value

3

Conversion

None

291

Step 15 Speed

Parameter 291 sets the rpm value for this step. (Scaling: 4096 =
Base Speed)

Parameter number

291

File:group

Profile Test Data

Parameter type

Setup

Display

+/- x.x rpm

Factory default

+0.0 rpm

Minimum value

-8 x base sp

Maximum value

+8 x base sp

Conversion

4096 = base sp

292

Step 15 Value

Parameter 292 sets the time in seconds for time steps, the
counts in units for encoder steps, and the TB3 input to trigger on
for TB Input steps. Scaling:

Time Step: 10 x desired value (10 = 1.0 sec)
Encoder Step: 10 = 1.0 units
TB Input Step: dependent on [L Option Mode Sel]. See P241.

Parameter number

292

File:group

Profile Test Data

Parameter type

Setup

Display

x.xS, x, x.x units

Factory default

0.0,0, 0.0

Minimum value

0.0,0, 0.0

Maximum value

3276.7, 5, 3276.7

Conversion

10=1.0 sec., x TBin, 10 = 1 unit

293

Step 15 Type

Parameter 293 selects the type of step to be used

0 = Not Used (This forces an End Action)
1 = Time Step, operate at speed shown in P291 for time in P292.
2 = TB3 Input Step, operate at speed shown in P291 until this
input goes true.
3 = Encoder Step, operate at speed shown in P291 for units in
P292.

Parameter number

293

File:group

Profile Test Data

Parameter type

Setup

Display

x

Factory default

0

Minimum value

0

Maximum value

3

Conversion

None