Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual
Page 281

Parameters
11-83
288
Step 14 Speed
Parameter 288 sets the rpm value for this step. (Scaling: 4096 =
Base Speed)
Parameter number
288
File:group
Profile Test Data
Parameter type
Setup
Display
+/- x.x rpm
Factory default
+0.0 rpm
Minimum value
-8 x base sp
Maximum value
+8 x base sp
Conversion
4096 = base sp
289
Step 14 Value
Parameter 289 sets the time in seconds for time steps, the
counts in units for encoder steps, and the TB3 input to trigger on
for TB Input steps. Scaling:
Time Step: 10 x desired value (10 = 1.0 sec)
Encoder Step: 10 = 1.0 units
TB Input Step: dependent on [L Option Mode Sel]. See P241
Parameter number
289
File:group
Profile Test Data
Parameter type
Setup
Display
x.xS, x, x.x units
Factory default
0.0,0, 0.0
Minimum value
0.0,0, 0.0
Maximum value
3276.7, 5, 3276.7
Conversion
10=1.0 sec., x TBin, 10 = 1 unit
290
Step 14 Type
Parameter 290 selects the type of step to be used
0 = Not Used (This forces an End Action)
1 = Time Step, operate at speed shown in P288 for time in P289.
2 = TB3 Input Step, operate at speed shown in P288 until this
input goes true.
3 = Encoder Step, operate at speed shown in P288 for units in
P289.
Parameter number
290
File:group
Profile Test Data
Parameter type
Setup
Display
x
Factory default
0
Minimum value
0
Maximum value
3
Conversion
None
291
Step 15 Speed
Parameter 291 sets the rpm value for this step. (Scaling: 4096 =
Base Speed)
Parameter number
291
File:group
Profile Test Data
Parameter type
Setup
Display
+/- x.x rpm
Factory default
+0.0 rpm
Minimum value
-8 x base sp
Maximum value
+8 x base sp
Conversion
4096 = base sp
292
Step 15 Value
Parameter 292 sets the time in seconds for time steps, the
counts in units for encoder steps, and the TB3 input to trigger on
for TB Input steps. Scaling:
Time Step: 10 x desired value (10 = 1.0 sec)
Encoder Step: 10 = 1.0 units
TB Input Step: dependent on [L Option Mode Sel]. See P241.
Parameter number
292
File:group
Profile Test Data
Parameter type
Setup
Display
x.xS, x, x.x units
Factory default
0.0,0, 0.0
Minimum value
0.0,0, 0.0
Maximum value
3276.7, 5, 3276.7
Conversion
10=1.0 sec., x TBin, 10 = 1 unit
293
Step 15 Type
Parameter 293 selects the type of step to be used
0 = Not Used (This forces an End Action)
1 = Time Step, operate at speed shown in P291 for time in P292.
2 = TB3 Input Step, operate at speed shown in P291 until this
input goes true.
3 = Encoder Step, operate at speed shown in P291 for units in
P292.
Parameter number
293
File:group
Profile Test Data
Parameter type
Setup
Display
x
Factory default
0
Minimum value
0
Maximum value
3
Conversion
None