14 logic input sts, 15 drive/inv status – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual
Page 211
Parameters
11-13
14
Logic Input Sts
Use Logic Input Sts to view drive logic operation. If a bit is set (1),
that function is enabled. If a bit is clear (0), that function is
disabled (not active).
The bits are defined as follows:
Parameter number
File:group
Monitor:Drive/Inv Status
Parameter type
source
Display
bits
Factory default
not applicable
Minimum value
00000000.00000000
Maximum value
11111111.11111111
Conversion
1 = 1
Bit
Description
0
Normal Stop
A ramp stop is selected.
1
Start
A start is in progress.
2
Jog 1
A jog 1 is in progress.
3
Clear Fault
A clear fault is in progress.
4
Forward
A forward was commanded.
Bit
Description
5
Reverse
A reverse was commanded.
6
Jog 2
A jog 2 is in progress.
7
Cur Lim Stop
A current limit stop is
selected.
8
Coast Stop
A coast stop is selected.
9
Spd Ramp Dis
Ramps are disabled.
Bit
Description
10
Flux Enable
Flux is enabled.
11
Process Trim
Process trim is enabled.
12
Speed Ref A
13
Speed Ref B
14
Speed Ref C
15
Reset Drive
The drive has been
commanded to reset.
C B A
0 0 0 No Change
0 0 1 Speed Ref 1
0 1 0 Speed Ref 2
0 1 1 Speed Ref 3
1 0 0 Speed Ref 4
1 0 1 Speed Ref 5
1 1 0 Speed Ref 6
1 1 1 Speed Ref 7
15
Drive/Inv Status
Use Drive/Inv Status to view the status/conditions within the
drive. When a bit is set (1), the corresponding condition in the
drive is true.
The bits are defined as follows:
Parameter number
File:group
Monitor:Drive/Inv Status
Parameter type
source
Display
bits
Factory default
not applicable
Minimum value
00000000.00000000
Maximum value
11111111.11111111
Conversion
1 = 1
1 If a warning has occurred, check the warning queue for more information.
2 If a fault has occurred, check the fault queue for more information.
C B A
0 0 0 No Change
0 0 1 Speed Ref 1
0 1 0 Speed Ref 2
0 1 1 Speed Ref 3
1 0 0 Speed Ref 4
1 0 1 Speed Ref 5
1 1 0 Speed Ref 6
1 1 1 Speed Ref 7
Bit
Description
0
Run Ready
The drive is ready to run. No
bits are set in Run Inhibit Sts
(parameter 16)
1
Running
The drive is following a
speed/torque reference
2
Command Dir
Shows which direction has
been requested; 1 is forward,
and 0 is reverse.
3
Rotating Dir
Shows the direction that the
motor is currently rotating; 1
is forward, and 0 is reverse.
Bit
Description
4
Accelerating
If 1, the motor is accelerating.
5
Decelerating
If 1, the motor is decelerating.
6
Warning
If 1, a warning has occurred.
7
Faulted
If 1, a fault has occurred.
8
At Set Speed
The motor is at the requested
speed.
9
Enable LED
The drive is enabled.
Bit
Description
10
Stopped
If 1, the drive is stopped.
11
Stopping
If 1, the drive is stopping.
12
At Zero Spd
Corresponds to Zero Speed
Tol (parameter 19).
13
Speed Ref A
14
Speed Ref B
15
Speed Ref C