beautypg.com

Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual

Page 334

background image

A-8

Specifications

Bit 0 — Normal Stop
Bit 1 — Start
Bit 2 — Jog 1
Bit 3 — Clear Fault
Bit 4 — Forward
Bit 5 — Reverse
Bit 6 — Jog 2
Bit 7 — Current Limit Stop
Bit 8 — Coast–to–Stop
Bit 9 — Speed Ramp Disable
Bit 10 — Flux Enable – Magnetizing Flux
Bit 11 — Process Trim Enable
Bit 12 — Speed Ref A
Bit 13 — Speed Ref B
Bit 14 — Speed Ref C
Bit 15 — Reset Drive

C B A
0 0 0 — No Change
0 0 1 — Speed Ref 1
0 1 0 — Speed Ref 2
0 1 1 — Speed Ref 3
1 0 0 — Speed Ref 4
1 0 1 — Speed Ref 5
1 1 0 — Speed Ref 6
1 1 1 — Speed Ref 7

Dir/Ref Owner (Par 128)
Start/Stop Owner (Par 129)
Jog1/Jog2 Owner (Par 130)
Ramp/ClFlt Owner (Par 131)
Flux/Trim Owner (Par 132)

Logic Input Sts (Par 14)

SP Enable Mask (Par 124)

Start/Jog Mask (Par 126)

Clr Flt/Res Mask (Par 127)

Dir/Ref Mask (Par 125)

Dir/Ref Mask (Par 125)

Clr Flt/Res Mask (Par 127)

SCANport 1

SCANport 2

SCANport 3

SCANport 4

SCANport 5

SCANport 6

(Gateway)

L Option Board

Logic Cmd Input

(parameter 197)

Bit 0 — Run Ready

Bit 8 — At Set Speed

Bit 1 — Running

Bit 9 — Enable LED

Bit 2 — Command Dir

Bit 10 — Stopped

Bit 3 — Rotating Dir

Bit 11 — Stopping

Bit 4 — Accelerating

Bit 12 — At Zero Spd

Bit 5 — Decelerating

Bit 13 — Speed Ref A

Bit 6 — Warning

Bit 14 — Speed Ref B

Bit 7 — Faulted

Bit 15 — Speed Ref C

C B A
0 0 0 — No Change
0 0 1 — Speed Ref 1
0 1 0 — Speed Ref 2
0 1 1 — Speed Ref 3
1 0 0 — Speed Ref 4
1 0 1 — Speed Ref 5
1 1 0 — Speed Ref 6
1 1 1 — Speed Ref 7

Drive/Inv Status (Par 15)