221 fault status 1, 222 fault status 2, 223 warning status 1 – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual
Page 269
Parameters
11-71
221
Fault Status 1
Fault Status 1 shows fault conditions that have been configured
to report as drive fault conditions. Each configuration bit matches
the bit definitions of Fault Select 1 (parameter 20) and Fault
Select 2 (parameter 22). When a bit is “1” the condition is true;
otherwise, the condition is false.
1 Fault Status 1 was added in Version 3.xx.
Parameter number
File:group
Monitor: Fault Status
Parameter type
source
Display
Bits
Factory default
0000 0000 0000 0000
Minimum value
0000 0000 0000 0000
Maximum value
1111 1111 1111 1111
Conversion
1 = 1
Refer to Chapter 12, Troubleshooting, for more information.
Bit
Condition
0
Ridethru Time
1
Prechrg Time
2
Bus Drop
3
Bus Undervlt
4
Bus Cycles>5
5
Open Circuit
Bit
Condition
6
Reserved
7
Reserved
8
mA Input
9
SP 1 Timeout
10
SP 2 Timeout
11
SP 3 Timeout
Bit
Condition
12
SP 4 Timeout
13
SP 5 Timeout
14
SP 6 Timeout
15
SP Error
222
Fault Status 2
Fault Status 2 shows fault conditions that have been configured
to report as drive fault conditions. Each configuration bit matches
the bit definitions of Fault Select 1 (parameter 20) and Fault
Select 2 (parameter 22). When a bit is “1” the condition is true;
otherwise, the condition is false.
1 Fault Status 2 was added in Version 3.xx.
Parameter number
File:group
Monitor: Fault Status
Parameter type
source
Display
Bits
Factory default
0000 0000 0000 0000
Minimum value
0000 0000 0000 0000
Maximum value
1111 1111 1111 1111
Conversion
1 = 1
Refer to Chapter 12, Troubleshooting, for more information.
Bit
Condition
0
SpdFdbk Loss
1
InvOvtmp Pnd
2
Reserved
3
MtrOvld Pend
4
MtrOvld Trip
5
Mtr Stall
Bit
Condition
6
Ext Fault In
7
Reserved
8
Reserved
9
Param Limit
10
Math Limit
11
Reserved
Bit
Condition
12
Reserved
13
InOvld Pend
14
Reserved
15
InvOvld Trip
223
Warning Status 1
Warning Status 1 shows warning conditions that have been
configured to report as drive warning conditions. Each
configuration bit matches the bit definitions of Warning Select 1
(parameter 21) and Warning Select 2 (parameter 23). When a bit
is “1” the condition is true; otherwise, the condition is false.
1 Warning Status 1 was added in Version 3.xx.
Parameter number
File:group
Monitor: Fault Status
Parameter type
source
Display
Bits
Factory default
0000 0000 0000 0000
Minimum value
0000 0000 0000 0000
Maximum value
1111 1111 1111 1111
Conversion
1 = 1
Refer to Chapter 12, Troubleshooting, for more information.
Bit
Condition
0
Ridethru Time
1
Prechrg Time
2
Bus Drop
3
Bus Undervlt
4
Bus Cycles>5
5
Open Circuit
Bit
Condition
6
Reserved
7
Reserved
8
mA Input
9
SP 1 Timeout
10
SP 2 Timeout
11
SP 3 Timeout
Bit
Condition
12
SP 4 Timeout
13
SP 5 Timeout
14
SP 6 Timeout
15
SP Error