Etc−mmi – Lenze ETC Motion Control User Manual
Page 326

ETC−MMI
Appendix
Cycle programming
7.8
7.8.2
l
326
EDSTCXN EN 2.0
Description
Term
Section
[L8000]
entry1 = P1200 = 1.23; top
entry1: for identification
P1200: definition of the corresponding P
field
1.23: value which is set in the P field
top: text for display and selection
entry2 = P1201= 2.34; bottom
entry3 = P1202= 3.45; middle
entry4 = c:\stdmmi\cnc20.bmp
Image file that can be displayed
[L8001]
entry1 = P1200= 1.23; Min; Max;
Flag; top
P1200=: definition of the corresponding
P field
1.23;: value which is set in the P field
Min;:minimum value that may be
entered
Max;: maximum value that may be
entered
Flag = 1: The value must be entered
top: text for display and selection
entry2 = P1201= 2.34;0;3.14;;
bottom
In this example, the software checks the
input for min/max. If there is no input,
the field is not entered in the DIN file.
entry3 = P1202= 3.45; middle
entry4 =
[L8002]
Entry0 =
c:\ProgramsLenze\ETC\mmi\Lenze.b
mp, 25
Name of an image file that can be
displayed. The 25 indicates that not half
the screen width, but only 25% of it is
available for the graphic. The value can
be entered in the range 0 ... 100%.
To ensure language independence, the display texts can also be taken from
a file other than delphmmi.ini. The source file is the file specified in the INI
file (e.g. delphmmi.ini) in the [config] section in the [language] entry
(without file extension ".txt").
Section
Term
Description
[Zyklen]
entry1 = L8000; #4100
The text with the no. 4100 from the file
sprache.txt is displayed here.
[L8000]
entry1 = P1200= 1.23; Min; Max;
Flag; #4151
The text with the no. 4151 from the file
sprache.txt is displayed here.
Language independence
Example