Interface PLC <˘> NC operating system
Extended interface for MMI functions
Data block 15
5.2
5.2.2
l
275
EDSTCXN EN 2.0
Data word
Name
Direction
Type of signal
036
General override for axes
HMI
→
NC
static
037
Override for spindle speeds
HMI
→
NC
static
038
Override for oscillation speed
HMI
→
NC
static
039
Override for PLC axes (Target
position approach)
HMI
→
NC
static
Definition of a signed evaluation factor for the currently valid traversing
speed. The specification is made in steps of 0.1 %.
Effect in the NC: The selected value is used as factor for evaluating the cur-
rently programmed maximum speed by the rough interpolator.
The override is effective in both manual as well as automatic operation. It
can be inhibited within a program via M functions.
Data word
Name
Direction
Type of signal
040−043
Speed preselection for traverse keys
HMI
→
NC
static
Definition of speed during modal traveling using the traverse keys. Specifi-
cation in [mm/min] as 64−bit floating point number.
Effect in the NC: The selected value is accepted at a fixed position in the para-
meter field. Every time the traverse key is actuated, the respective axis is mo-
ved modally at the speed entered.
Data word
Name
Direction
Type of signal
044−047
Increment preselection
HMI
→
NC
static
Definition of increment during manual traversing in inching mode. Specifi-
cation in [mm] or [inch] as 64−Bit floating point number.
Effect in the NC: The selected value is accepted at a fixed position in the para-
meter field. Every time the traverse key is actuated, the respective axis is mo-
ved about the delta specified.