Interface PLC <˘> NC operating system
Definitions
Data block 1
5.1
5.1.2
l
264
EDSTCXN EN 2.0
Data word
Name
Direction
Type of signal
150.00
Strobe M function
NC
→
PLC
Strobe
The signal is set to "0" if the data word is valid for the "M function". It is set
to value "1" if the acknowledgement signal of the PLC has changed from "1"
to "0". After switching on the control, the signal has the value "1".
Effect in the PLC: If the signal has the value "0", the data word of the "M func-
tion" is accepted. The acknowledgement signal is set to the value "0" after
acceptance. If the strobe has value "1", the acknowledgement signal is set to
"1".
In the case of synchronized M functions, the "Read enable" signal is with-
drawn. This takes place before the acknowledgement signal is set.
Data word
Name
Direction
Type of signal
151
M function
NC
→
PLC
Message
The data word contains the number of the M function in binary representa-
tion (0 ... 9999). The M function can be programmed in the parts program or
generated by pressing the key.
The numbers of the M functions are partially defined by standards (DIN
66025); the free numbers can be assigned application−specifically. For a list
of defined M−numbers for the ETC including description, refer to the ETC pro-
gramming NC operating system.
Effect in the PLC: Execution of the function specified via the M function. Read
enable is activated after the function has been completed or at another sui-
table point in time.
Data word
Name
Direction
Type of signal
159.00
Strobe H function
NC
→
PLC
Strobe
The signal is set to "0" if the data word is valid for the "H function". It is set
to value "1" if the acknowledgement signal of the PLC has changed from "1"
to "0". After switching on the control, the signal has the value "1".
Effect in the PLC: If the signal has the value "0", the data word of the "H func-
tion" is accepted. The acknowledgement signal is set to the value "0" after
acceptance. If the strobe has value "1", the acknowledgement signal is set to
"1".
If the data acceptance takes longer (>10 sec.), the "Read enable" signal must
be withdrawn. This must take place before the acknowledgement signal is
set.