3 mk_ncprog_ohne_kommentare, 4 mk_ncprog_nicht_ins_eeprom, 5 mk_metrisch – Lenze ETC Motion Control User Manual
Page 194: Mk_ncprog_ohne_kommentare, Mk_ncprog_nicht_ins_eeprom, Mk_metrisch, Machine constants

Machine constants
Software configuration
MK_NCPROG_OHNE_KOMMENTARE
4.3
4.3.3
l
194
EDSTCXN EN 2.0
4.3.3
MK_NCPROG_OHNE_KOMMENTARE
This machine constant suppresses the storage of comments and spaces in
DIN programs. All comments in curly brackets are deleted and groups of
more than one space are reduced to one. This is probably recommended for
reasons of saving memory space in Flash−PROM of the control. However, this
setting is only suitable if the programs do not have to be viewed or changed
in the control.
Value
Meaning
0
Transfer of DIN programs to Flash−PROM without changes (default).
1
Prior to saving in Flash−PROM, delete comments and reduce program.
)
Note!
If DIN programs are retransferred to the PC and this retransfer
overwrites the original program on the PC, comments will also
be deleted in this case.
4.3.4
MK_NCPROG_NICHT_INS_EEPROM
This machine constant prevents the transfer of programs to the internal
Flash−PROM during the transmission of DIN programs via the monitor
interface. This option must always be selected if the field of application of
the control requires that new DIN programs are read in continuously via the
monitor interface, which are no longer required after the machine is
switched off. This is normally the standard procedure on machines for
individual order processing.
Value
Meaning
0
Automatically transfer DIN programs to Flash−PROM (default).
1
Do not store DIN programs in Flash−PROM.
As the rams can only take a limited number of write cycles (approx. 100000),
it is recommended in the above−mentioned case to set these MCs to 1.
4.3.5
MK_METRISCH
This machine constant selects one of the two measuring systems for all
position and speed specifications. This applies to all input and output values
for positions and speeds except the machine constants themselves.
Irrespective of their contents, these must always be entered in the metrical
system.
Value
Meaning
0
Dimensions according to MK_CONST_REL_INCH [inch] or [inch/min]
1
Dimensions according to MK_CONST_REL_MM [mm] or [mm/min] (default)