Cnc programming – Lenze ETC Motion Control User Manual
Page 185
CNC programming
Data fields
P field
3.5
3.5.1
l
185
EDSTCXN EN 2.0
Unit
Sync
Meaning
Index
588
Current processing state of channel N for diagnosis
purposes
0: Idle
1: Run
2: Brake termination
3: Termination wait quit
4: Termination
5: Brake interrupt
6: Interrupt
7: Brake block jump
8: Block jump
9: Brake interrupt
10: Interrupt
11: Brake error
12: Error
13: Balancing run
x
589
Current increment, e.g. stitch length during sewing
x
mm *
590
Current interpreter state
0: No program active
1: Single function active
2: Program active
3: Interrupt program active
x
−−−
591
Bit coded state of modal functions
Bit0: 0=route operation (G30), 1=path operation (G31)
Bit1: 0=empty run (M15,M16,M21), 1=profile (M14)
Bit2: 0=event handler disabled (G132), 1=event handler
enabled (G133)
Bit3: 0=override enabled (M48), 1=override disabled
(M49)
x
−−−
592
Current line number (not block number) in the NC
program
x
−−−
593
Current setpoint speed, e.g. for a spindle. Corresponds
to the value programmed for address E in the DIN block
(G0−G3).
x
−−−
594
Number of the M function, by which the last
subprogram call was triggered. For use in cycles, which
are called by M functions (MK_MFKT_UPR_TABELLE).
−−−
595
Last output H function number
x
−−−
596
Current number of preprocessed blocks in the block
search buffer
−−−
597
Geometry counter for block progress display
x
−−−
598
Progress display for current traversing block:
0: Block start
1: Block end
x
−−−
599
Efficiency of geometry filter G200 in %
x
%
610
Size of the free memory for managing NC programs
Byte
611
Size of the free memory for managing symbolic
program numbers
Byte
612
Number of pending and not yet confirmed error
messages
613
Value of MK_S_VERSATZSPERRE from the machine
constants
666 ... 669
Current value of override 0 ... 3
670
Maximum value of the acceleration ramp on the path,
see G201
m/s
2
671
Maximum value of the deceleration ramp on the path,
see G201
m/s
2
672
Speed preselection for modal travel
x
Unit/min
673
Increment specification for step travel
Unit