2 extended interface for mmi functions, 1 data blocks 8, Extended interface for mmi functions – Lenze ETC Motion Control User Manual
Page 270: Data blocks 8, Interface plc <˘> nc operating system, Extended interface for mmi functions data blocks 8
![background image](/manuals/566331/270/background.png)
Interface PLC <˘> NC operating system
Extended interface for MMI functions
Data blocks 8 ... 14
5.2
5.2.1
l
270
EDSTCXN EN 2.0
5.2
Extended interface for MMI functions
5.2.1
Data blocks 8 ... 14
DB8 data word
Name
Direction
DW000 − 255
reserved
DB9 data word
Name
Direction
DW000 − 255
reserved
DB10 data word
Name
Direction
DW000 − 255
reserved
DB11 data word
Name
Direction
DW000 − 247
reserved
DW250 − 253
Target position block axis 0
PLC
←
NC
DW254 − 255
Target position block axis 1 (LOW−WORD)
PLC
←
NC
DB12 data word
Name
Direction
DW000 − 255
reserved
DW000 − 001
Target position block axis 1 (HIGH−WORD)
PLC
←
NC
SW002 − 005
Target position block axis 2
PLC
←
NC
DW006 − 009
Target position block axis 3
PLC
←
NC
DW010 − 013
Target position block axis 4
PLC
←
NC
DW014 − 017
Target position block axis 5
PLC
←
NC
DW018 − 021
Target position block axis 6
PLC
←
NC
DW022 − 025
Target position block axis 7
PLC
←
NC
DW026 − 029
Target position block axis 8
PLC
←
NC
DW030 − 033
Target position block axis 9
PLC
←
NC
DW034 − 037
Target position block axis 10
PLC
←
NC
DW038 − 041
Target position block axis 11
PLC
←
NC
DW042 − 045
Distance between current zero point and home position
axis 0
PLC
←
NC
DW046 − 049
Distance between current zero point and home position
axis 1
PLC
←
NC
DW050 − 053
Distance between current zero point and home position
axis 2
PLC
←
NC
DW054 − 057
Distance between current zero point and home position
axis 3
PLC
←
NC
DW058 − 061
Distance between current zero point and home position
axis 4
PLC
←
NC
DW062 − 065
Distance between current zero point and home position
axis 5
PLC
←
NC
DW066 − 069
Distance between current zero point and home position
axis 6
PLC
←
NC
DW070 − 072
Distance between current zero point and home position
axis 7
PLC
←
NC
DW074 − 077
Distance between current zero point and home position
axis 8
PLC
←
NC
DW078 − 081
Distance between current zero point and home position
axis 9
PLC
←
NC
DW082 − 085
Distance between current zero point and home position
axis 10
PLC
←
NC
Assignment